System Health Monitor - Supero H8DM3-2 User Manual

Supero
Table of Contents

Advertisement

H8DM3-2/H8DMi-2 User's Manual
Redirection After BIOS POST
Options are Disable (no redirection after BIOS POST), Boot Loader (redirection
during POST and during boot loader) and Always (redirection always active). Note
that some OS's may not work with this set to Always.
Terminal Type
Selects the type of the target terminal. Options are ANSI, VT100 and VT-UTF8.
VT-UTF8 Combo Key Support
Allows you to Enable or Disable VT-UTF8 combination key support for ANSI/VT100
terminals.
Sredir Memory Display Delay
Use this setting to set the delay in seconds to display memory information. Options
are No Delay, 1 sec, 2 secs and 4 secs.

System Health Monitor

CPU Overheat Alarm
Use the "+" and "-" keys to set the CPU temperature threshold to between 65
o
and 90
C. When this threshold is exceeded, the overheat LED on the chas-
sis will light up and an alarm will sound. The LED and alarm will turn off once
the CPU temperature has dropped to 5 degrees below the threshold set. The
default setting is 72
The submenu includes monitor displays for the following information:
CPU1 Temperature, CPU2 Temperature (for dual CPU systems), System Tem-
perature, VCore1, VCore2 (for dual CPU systems), 3.3V, +5Vin, +12Vin, 5V stby
and battery voltage.
System Fan Monitor
Fan Speed Control Modes
This feature allows the user to determine how the system will control the speed of
the onboard fans. Select "Workstation" if your system is used as a Workstation.
Select "Server" if your system is used as a Server. Select "Disable" to disable
the fan speed control function to allow the onboard fans to continuously run at
full speed (12V). The options are 1) Disabled (Full Speed)
and 3) Workstation Mode.
o
C.
4-16
o
2) Server Mode

Advertisement

Table of Contents
loading

This manual is also suitable for:

H8dmi-2

Table of Contents