Summary of Contents for Supero H8DGT-HF

  • Page 1 ® UPER H8DGT-HF H8DGT-HIBQF USER’S MANUAL Revision 1.1c...
  • Page 2 The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, and makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
  • Page 3: About This Manual

    PC users. It provides information for the installation and use of the H8DGT-HF/HIBQF serverboards. The H8DGT-HF/HIBQF serverboard is based on the AMD® SR5670/SP5100 chipset and supports dual AMD Socket G34 type processors with up to 128 GB of ECC/Non-ECC UDIMM or up to 512 GB of ECC RDIMM/LRDIMM DDR3-1600/1333/1066 MHz SDRAM in 16 DIMMs.
  • Page 4 H8DGT-HF/HIBQF SERVERBOARD USER'S MANUAL Notes...
  • Page 5: Standardized Warning Statements

    Standardized Warning Statements Standardized Warning Statements About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance.
  • Page 6 H8DGT-HF/HIBQF SERVERBOARD USER'S MANUAL Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant. ¡Advertencia! Existe peligro de explosión si la batería se reemplaza de manera incorrecta.
  • Page 7: Product Disposal

    Standardized Warning Statements Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations. 警告 本产品的废弃处理应根据所有国家的法律和规章进行。 警告 本產品的廢棄處理應根據所有國家的法律和規章進行。 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
  • Page 8 H8DGT-HF/HIBQF SERVERBOARD USER'S MANUAL Notes viii...
  • Page 9: Table Of Contents

    Table of Contents Chapter 1 Introduction Overview ......................1-1 Checklist ......................1-1 Contacting Supermicro ..................1-2 H8DGT-HF/HIBQF Quick Reference .............. 1-5 Chipset Overview .................... 1-9 AMD SR5670/SP5100 Chipset ............... 1-9 HyperTransport Technology ................1-9 PC Health Monitoring ..................1-9 Power Confi guration Settings................ 1-10 Power Supply ....................1-11...
  • Page 10 H8DGT-HF/HIBQF SERVERBOARD USER'S MANUAL Jumper Settings .................... 2-12 Explanation of Jumpers ................2-12 CMOS Clear ..................... 2-12 I2C to PCI-Express Slot ................2-13 Watch Dog Enable/Disable ..............2-13 VGA Enable/Disable ................. 2-13 BMC Jumper .................... 2-13 LAN1/2 Enable/Disable ................2-13 Onboard Indicators ..................
  • Page 11 Table of Contents Chapter 4 BIOS Introduction ...................... 4-1 Main Menu ...................... 4-2 Advanced Settings Menu ................4-2 Security Menu ....................4-15 Boot Menu ..................... 4-16 Exit Menu ...................... 4-17 Appendix A BIOS Error Beep Codes Appendix B BIOS POST Checkpoint Codes Uncompressed Initialization Codes ..............
  • Page 12 H8DGT-HF/HIBQF SERVERBOARD USER'S MANUAL Notes...
  • Page 13: Chapter 1 Introduction

    If anything listed here is damaged or missing, contact your retailer. • One (1) H8DGT-HF/HIBQF serverboard Note: For your system to work properley, please follow the links below to download all necessary drivers/utilities and the user’s manual for your server.
  • Page 14: Contacting Supermicro

    H8DGT-HF/HIBQF Serverboard User’s Manual Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 15 Chapter 1: Introduction Figure 1-1. H8DGT-HF/HIBQF Image...
  • Page 16 H8DGT-HF/HIBQF Serverboard User’s Manual Figure 1-2. H8DGT-HF/HIBQF Motherboard Layout (not drawn to scale) COM1 JIB1 Mellonox Connect-X JI2C1 JI2C2 SR5670 JBT1 SP5100 Battery CPU1 CPU2 Notes: Jumpers not indicated are for test purposes only. Not all ports, jumpers or LED Indicators are available on all serverboards.
  • Page 17: H8Dgt-Hf/Hibqf Quick Reference

    Chapter 1: Introduction H8DGT-HF/HIBQF Quick Reference Jumper Description Default Setting JBT1 CMOS Clear (See Section 2-7) JIB1 Infi niBand Enable/Disable Pins 1-2 (Enabled) C1/JI C to PCI-E Slot Enable/Disable Both Open (Disabled) BMC Enable/Disable Pins 1-2 (Enabled) JPG1 VGA Enable/Disable...
  • Page 18: Motherboard Features

    H8DGT-HF/HIBQF Serverboard User’s Manual Motherboard Features • Dual AMD Opteron 6000 series (AMD Socket G34 type) processors Note: You must install at least two processors for full functions to be supported. Memory • Sixteen (16) single/dual/tri/quad channel DIMM slots supporting up...
  • Page 19 Chapter 1: Introduction ACPI Features • Microsoft OnNow • Slow blinking LED for suspend state indicator • BIOS support for USB keyboard • Internal/external modem ring-on • Hardware BIOS Virus protection Onboard I/O • Two (2) Fast UART 16550 compatible serial port (one header and one port) •...
  • Page 20: System Block Diagram

    H8DGT-HF/HIBQF Serverboard User’s Manual Figure 1-3. AMD SR5670/SP5100 Chipset: System Block Diagram Note: This is a general block diagram and may not exactly represent the features on your motherboard. See the previous pages for the actual specifi cations of your motherboard.
  • Page 21: Chipset Overview

    The end result is a signifi cant increase in bandwidth within the chipset. PC Health Monitoring This section describes the PC health monitoring features of the H8DGT-HF/HIBQF serverboard. The serverboard has an onboard System Hardware Monitor chip that supports PC health monitoring.
  • Page 22: Power Confi Guration Settings

    H8DGT-HF/HIBQF Serverboard User’s Manual CPU Overheat/Fan Fail LED and Control This feature is available when the user enables the CPU overheat/Fan Fail warning function in the BIOS. This allows the user to defi ne an overheat temperature. When this temperature is exceeded or when a fan failure occurs, the Overheat/Fan Fail warning LED is triggered.
  • Page 23: Power Supply

    It is even more important for processors that have high CPU clock rates. The H8DGT-HF/HIBQF serverboard requires the use of proprietary power supplies. Please refer to the pinout information for the power connectors in Section 6 of Chapter 2 for detailed information on power requirements.
  • Page 24 H8DGT-HF/HIBQF Serverboard User’s Manual 1-12...
  • Page 25: Chapter 2 Installation

    Chapter 2: Installation Chapter 2 Installation Static-Sensitive Devices Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent damage to your system board, it is important to handle it very carefully. The following measures are generally suffi cient to protect your equipment from ESD. Precautions •...
  • Page 26: Processor And Heatsink Installation

    H8DGT-HF/HIBQF Serverboard User's Manual Processor and Heatsink Installation Caution: Exercise extreme caution when handling and installing the processor. Always connect the power cord last and always remove it before adding, removing or changing any hardware components. Installation Procedure Follow the procedures as listed below to install the motherboard into a chassis.
  • Page 27 Chapter 2: Installation 3. Use your thumb and your index fi nger to hold the CPU. Locate and align pin 1 of the CPU socket with pin 1 of the CPU. Both are marked with a triangle. 4. Align pin 1 of the CPU with pin 1 of the socket.
  • Page 28: Mounting The Motherboard Into A Chassis

    Check the Compatibility of the Motherboard Ports and the I/O Shield 1. The H8DGT-HF/HIBQF serverboard requires a chassis that can support a board of (LxW) 6.8" x 16.64" (172 x 423 mm) in size. It was designed to be used in a Supermicro 2U Twin system.
  • Page 29 (128-bit) memory, which is faster than non-interleaved (64-bit) memory. Maximum Memory The H8DGT-HF/HIBQF serverboard can support a maximum memory size of up to 128 GB of ECC/Non-ECC UDIMM or up to 512 GB of ECC RDIMM/LRDIMM SDRAM.
  • Page 30: Dimm Module Population Confi Guration

    H8DGT-HF/HIBQF Serverboard User's Manual Memory Population for Optimal Performance -For a Motherboard with One CPU (CPU1) Installed # DIMMS Channel 1 Channel 2 Channel 3 Channel 4 4 DIMMs CPU1 P1-1A P1-2A P1-3A P1-4A 8 DIMMs CPU1 P1-1A P1-1B P1-2A...
  • Page 31: Pci Expansion Cards

    Chapter 2: Installation Possible System Memory Allocation & Availability System Device Size Physical Memory Available (4 GB Total System Memory) Firmware Hub fl ash memory (System BIOS) 1 MB 3.99 GB Local APIC 4 KB 3.99 GB Area Reserved for the chipset 2 MB 3.99 GB I/O APIC (4 Kbytes)
  • Page 32: I/O Port And Control Panel Connections

    H8DGT-HF/HIBQF Serverboard User's Manual I/O Port and Control Panel Connections The I/O ports are color coded in conformance with the PC99 specifi cation to make setting up your system easier. See Figure 2-2 below for the colors and locations of the various I/O ports.
  • Page 33: Connector Defi Nitions

    Chapter 2: Installation Connector Defi nitions Universal Serial Bus Ports Universal Serial Bus Ports Pin Defi nitions (USB 0/1, Two Universal Serial Bus ports (USB 2.0) are USB4) located beside the LAN1 port (USB0/1). One USB0/1 USB4 additional Type A port (USB4) is included on Pin # Defi...
  • Page 34: Chassis Intrusion

    H8DGT-HF/HIBQF Serverboard User's Manual Chassis Intrusion Chassis Intrusion Pin Defi nitions (JL1) A Chassis Intrusion header is located at JL1. Pin# Defi nition Attach the appropriate cable to inform you of Battery voltage a chassis intrusion. Intrusion signal Overheat LED Overheat LED Pin Defi...
  • Page 35: Trusted Platform Module Header

    Chapter 2: Installation Trusted Platform Module Header Trusted Platform Module Header Pin Defi nitions This header is used to connect a Trusted (JTPM1) Platform Module (TPM), available separately Pin# Defi nition Pin# Defi nition from a third-party vendor. A TPM is a LCLK security device that allows encryption and LFRAME...
  • Page 36: H8Dgt-Hf/Hibqf Serverboard User's Manual

    H8DGT-HF/HIBQF Serverboard User's Manual Jumper Settings Connector Pins Explanation of Jumpers To modify the operation of the motherboard, Jumper jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function Setting of the connector. Pin 1 is identifi ed with a square solder pad on the printed circuit board.
  • Page 37: I2C To Pci-Express Slot

    Chapter 2: Installation I2C to PCI-Express Slot C to PCI-Express Slot Jumper Settings C1/JI C2 allows you to enable the I C bus (JI2C1/JI2C2) to communicate with the PCI-Express slot. Jumper Setting Defi nition For the jumpers to work properly, please set Closed Enabled both jumpers to the same setting.
  • Page 38: Onboard Indicators

    H8DGT-HF/HIBQF Serverboard User's Manual Onboard Indicators LAN LED (Connection Speed Indicator) LAN1/LAN2 LEDs LED Color Defi nition The Ethernet ports (located beside the Serial 10 MHz port) have two LEDs. On each Gb LAN port, Green 100 MHz one LED blinks to indicate activity while the...
  • Page 39: Infi Niband Led Indicators

    Chapter 2: Installation Infi niBand LED Indicators Infi niBand LED (LE2) Activity LED Two Infi niBand LED indicators (LE2/LE3) Color Status Defi nition are located near the Infi niBand port of the Green Solid Infi niBand Connected H8DGT-HIBQF Serverboard. The green No Connection LED (LE2) is the Infi...
  • Page 40: 2-11 Enabling Sata Raid

    H8DGT-HF/HIBQF Serverboard User's Manual 2-11 Enabling SATA RAID Now that the hardware is set up, you must install the operating system and the SATA RAID drivers, if you wish to use RAID with your SATA drives. The installation procedure differs depending on whether you wish to have the operating system installed on a RAID array or on a separate non-RAID drive.
  • Page 41: Enabling Sata Raid In The Bios

    Chapter 2: Installation Enabling SATA RAID in the BIOS Before installing the Windows Operating System, you must change some settings in BIOS. Boot up the system and hit the <Del> key to enter the BIOS Setup Utlility. After the Setup Utility loads, 1.
  • Page 42: Using The Adaptec Raid Utility

    H8DGT-HF/HIBQF Serverboard User's Manual Figure 2-4.Adaptec RAID Utility Program Screen Using the Adaptec RAID Utility The Adaptec RAID Utility program is where you can defi ne the drives you want to include in the RAID array and the mode and type of RAID.
  • Page 43: 2-12 Installing Drivers

    Chapter 2: Installation 2-12 Installing Drivers The Supermicro Website contains drivers and utilities for your system at ftp://ftp. supermicro.com, some of which must be installed, such as the chipset driver. After downloading and installing the drivers and utilities, the display shown in Figure 2-6 should appear.
  • Page 44: Supero Doctor Iii

    SuperDoctor, as the SuperDoctor settings override the BIOS settings. To set the BIOS temperature threshold settings again, you would fi rst need to uninstall SuperDoctor. Figure 2-6. Supero Doctor III Interface Display Screen (Health Information) 2-20...
  • Page 45 Chapter 2: Installation Figure 2-7. Supero Doctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/software/ SuperDoctorIII.cfm.For Linux, we recommend that you use the SuperoDoctor II application instead.
  • Page 46: 2-13 Serverboard Battery

    H8DGT-HF/HIBQF Serverboard User's Manual 2-13 Serverboard Battery Caution: There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 2-8). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032).
  • Page 47: Chapter 3 Troubleshooting

    Chapter 3: Troubleshooting Chapter 3 Troubleshooting Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the ‘Technical Support Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter. Always disconnect the AC power cord before adding, changing or installing any hardware components.
  • Page 48: No Video

    H8DGT-HF/HIBQF Serverboard User's Manual No Video 1. If the power is on but you have no video, remove all the add-on cards and cables. 2. Use the speaker to determine if any beep codes exist. Refer to Appendix A for details on beep codes.
  • Page 49: Frequently Asked Questions

    Question: What type of memory does my motherboard support? Answer: The H8DGT-HF/HIBQF serverboard supports a maximum of u p t o 1 2 8 G B o f E C C / N o n - E C C U D I M M o r u p t o 5 1 2 G B o f E C C R D I M M / L R D I M M D D R 3 - 1 6 0 0 / 1 3 3 3 / 1 0 6 6 M H z s p e e d a n d 1 GB, 2 GB, 4 GB, 8 GB, 16 GB or 32 GB size SDRAM in sixteen (16) DIMMs.
  • Page 50: Returning Merchandise For Service

    H8DGT-HF/HIBQF Serverboard User's Manual command "fl ash" (without quotation marks) then type in the BIOS fi le that you want to update with (xxxx.rom). Question: What's on the CD that came with my motherboard? Answer: The supplied compact disc has quite a few drivers and programs that will greatly enhance your system.
  • Page 51: Chapter 4 Bios

    Chapter 4 BIOS Introduction This chapter describes the AMIBIOS™ Setup utility for the H8DGT-HF/HIBQF serverboard. The AMI ROM BIOS is stored in a fl ash chip and can be easily upgraded using a fl oppy disk-based program. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual.
  • Page 52: Main Menu

    H8DGT-HF/HIBQF Serverboard User’s Manual Main Menu When you fi rst enter AMI BIOS Setup Utility, you will see the Main Menu screen. You can always return to the Main Menu by selecting the Main tab on the top of the screen with the arrow keys.
  • Page 53 Chapter 4: BIOS Wait for F1 if Error This setting controls the system response when an error is detected during the boot sequence. When enabled, BIOS will stop the boot sequence when an error is detected, at which point you will need to press the F1 button to re-enter the BIOS setup menu.
  • Page 54 H8DGT-HF/HIBQF Serverboard User’s Manual GART Error Reporting This option should remain disabled for normal operation. The driver developer may enable this option for testing purposes. Options are Enabled or Disabled. Microcode Update This setting Enables or Disables microcode updating. Secure Virtual Machine Mode This setting is used to Enable or Disable SVM.
  • Page 55 Chapter 4: BIOS   Advanced Chipset Control Confi guration  NorthBridge Confi guration  Memory Confi guration Bank Interleaving Select Auto to automatically enable a bank-interleaving memory scheme when this function is supported by the processor. The options are Auto and Disabled.
  • Page 56 H8DGT-HF/HIBQF Serverboard User’s Manual DRAM ECC Enable This setting allows hardware to report and correct memory errors automatically, maintaining system integrity. Options are Enabled or Disabled.  DRAM Timing Confi guration DRAM Timing Confi g This setting specifi es the DRAM timing confi guration. Options are Auto and Manual.
  • Page 57 Chapter 4: BIOS On Chip SATA Type Use this setting to set the On Chip SATA type. Options include Native IDE, RAID, AMD_AHCI and Legacy IDE. SATA IDE Combined Mode This setting allows you to Enable or Disable the SATA IDE combined mode. PATA Channel Confi...
  • Page 58 H8DGT-HF/HIBQF Serverboard User’s Manual DMA Mode Selects the DMA Mode. Options are Auto, SWDMA0, SWDMA1, SWDMA2, MWDMA0. MDWDMA1, MWDMA2, UDMA0. UDMA1, UDMA2, UDMA3, UDMA4 and UDMA5. (SWDMA=Single Word DMA, MWDMA=Multi Word DMA, UDMA=UltraDMA.) S.M.A.R.T. Self-Monitoring Analysis and Reporting Technology (SMART) can help predict impending drive failures.
  • Page 59 Chapter 4: BIOS Onboard Infi niBand Controller This option Enables or Disables the onboard Infi niBand controller. Onboard VGA Controller This option Enables or Disables the onboard VGA controller. Onboard LAN Controller This option Enables or Disables the onboard LAN controller. ROM Scan Ordering This setting determines which kind of option ROM activates prior to another.
  • Page 60 H8DGT-HF/HIBQF Serverboard User’s Manual Serial 2 Address This option specifi es the base I/O port address and Interrupt Request address of serial port 2. Select "Disabled" to prevent the serial port from accessing any system resources. When this option is set to "Disabled", the serial port physically becomes unavailable.
  • Page 61 Chapter 4: BIOS Terminal Type Selects the type of the target terminal. Options are ANSI, VT100 and VT-UTF8. VT-UTF8 Combo Key Support Allows you to Enable or Disable VT-UTF8 combination key support for ANSI/ VT100 terminals. Sredir Memory Display Delay Use this setting to set the delay in seconds to display memory information.
  • Page 62 H8DGT-HF/HIBQF Serverboard User’s Manual Note: Only CPU temperature (Low, Medium, High) and system temperature (RT1) are required to be displayed in BIOS and in-system monitoring software. Other Motherboard components such as memory, chipset, SAS and 10Gb controllers, and others are not requried to display temperatures. For debugging and testing purposes, BIOS and system monitoring software can show motherboard components’...
  • Page 63: View Bmc System Event Log

    Chapter 4: BIOS  ACPI Confi guration ACPI Aware O/S This setting Enables or Disables ACPI support for the system's operating system. Options include Yes (enabled) or No (disabled). ACPI APIC Support Determines whether to include the ACPI APIC table pointer in the RSDT pointer list.
  • Page 64 H8DGT-HF/HIBQF Serverboard User’s Manual IP Address Source Select the source of this machine's IP address. If Static is selected, you will need to know and enter manually the IP address of this machine below. If DHCP is selected, the BIOS will search for a DHCP (Dynamic Host Confi...
  • Page 65: Security Menu

    Chapter 4: BIOS  Event Log Confi guration View Event Log Pressing the Enter key will open the event log. Use the "" and "" keys to navigate through the system event log. Mark All Events as Read Selecting this and pressing the Enter key marks all events as read in the event log.
  • Page 66: Boot Menu

    H8DGT-HF/HIBQF Serverboard User’s Manual Boot Menu The Boot Menu is accessible only when the "Load Onboard LAN Option ROM" setting (in the PCI/PnP Confi guration menu) is enabled.  Boot Device Priority This feature allows you to prioritize the boot sequence from the list of available devices.
  • Page 67: Exit Menu

    Chapter 4: BIOS Exit Menu Select the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen. Save Changes and Exit When you have completed the system confi guration changes, select this option to leave BIOS Setup and reboot the computer, so the new system confi guration parameters can take effect.
  • Page 68 H8DGT-HF/HIBQF Serverboard User’s Manual Notes 4-18...
  • Page 69: Appendix A Bios Error Beep Codes

    Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
  • Page 70 H8DGT-HF/HIBQF Serverboard User’s Manual Notes...
  • Page 71: Appendix B Bios Post Checkpoint Codes

    Appendix B: BIOS POST Checkpoint Codes Appendix B BIOS POST Checkpoint Codes When AMIBIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, diagnostic equipment can be attached to the computer to read I/O port 0080h. B-1 Uncompressed Initialization Codes The uncompressed initialization checkpoint codes are listed in order of execution: Checkpoint...
  • Page 72: B-2 Bootblock Recovery Codes

    H8DGT-HF/HIBQF Serverboard User’s Manual B-2 Bootblock Recovery Codes The bootblock recovery checkpoint codes are listed in order of execution: Checkpoint Code Description The onboard fl oppy controller if available is initialized. Next, beginning the base 512 KB memory test. Initializing the interrupt vector table next.
  • Page 73: B-3 Uncompressed Initialization Codes

    Appendix B: BIOS POST Checkpoint Codes B-3 Uncompressed Initialization Codes The following runtime checkpoint codes are listed in order of execution. These codes are uncompressed in F0000h shadow RAM. Checkpoint Code Description The NMI is disabled. Next, checking for a soft reset or a power on condition. The BIOS stack has been built.
  • Page 74 H8DGT-HF/HIBQF Serverboard User’s Manual Checkpoint Code Description Completed post-video ROM test processing. If the EGA/VGA controller is not found, performing the display memory read/write test next. The EGA/VGA controller was not found. The display memory read/write test is about to begin.
  • Page 75 Appendix B: BIOS POST Checkpoint Codes Checkpoint Code Description Shutdown was successful. The CPU is in real mode. Disabling the Gate A20 line, parity, and the NMI next. The A20 address line, parity, and the NMI are disabled. Adjusting the memory size depending on relocation and shadowing next.
  • Page 76 H8DGT-HF/HIBQF Serverboard User’s Manual Checkpoint Code Description Any initialization required after the option ROM test has completed. Confi guring the timer data area and printer base address next. Set the timer and printer base addresses. Setting the RS-232 base address next.

This manual is also suitable for:

H8dgt-hibqf

Table of Contents