Citizen REF CH-452 Instruction Manual
Citizen REF CH-452 Instruction Manual

Citizen REF CH-452 Instruction Manual

Digital blood pressure monitor
Hide thumbs Also See for REF CH-452:

Advertisement

INSTRUCTION MANUAL
FOR
DIGITAL BLOOD PRESSURE MONITOR
CH-452
REF
English
1202

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the REF CH-452 and is the answer not in the manual?

Questions and answers

Summary of Contents for Citizen REF CH-452

  • Page 1 INSTRUCTION MANUAL DIGITAL BLOOD PRESSURE MONITOR CH-452 English 1202...
  • Page 2: Table Of Contents

    Contents GENERAL REMARKS 3 - GENERAL REMARKS General remarks on blood pressure and blood pressure measurement 5 - PRECAUTIONS FOR USE AND MAINTENANCE To defl ate the cuff quickly, press the “START/STOP” switch. 8 - IDENTIFICATION OF PARTS Before applying your blood pressure cuff, be sure you have selected the 10 - LOADING THE BATTERIES appropriate size cuff: Cuff (model: SCN-003) fi...
  • Page 3: General Remarks

    PRECAUTIONS FOR USE AND MAINTENANCE GENERAL REMARKS Measure your blood pressure when you are relaxed and still. Keep the center of Precautions for use the cuff at the level of your heart and DO NOT move your arm or talk. If you suffer from heart disease, high blood pressure or other circulatory disease, consult your physician before using the monitor.
  • Page 4 Please contact a distributor. : Keep dry : Warning : Refer to instruction manual before use Name : CITIZEN SYSTEMS JAPAN CO., LTD. : Appliance compliance WEEE directive Address : 6-1-12, Tanashi-cho, Nishi-Tokyo-Shi, : Accumulators and battery packs for separate collection...
  • Page 5: Identification Of Parts

    IDENTIFICATION OF PARTS IDENTIFICATION OF PARTS Component names <Main Unit> <Cuff> Systolic blood pressure display Diastolic blood pressure/Pulse Air hose display Blue marker MEMORY Switch Metal hoop Air hose connector Air hose socket START/STOP Switch w Stand-by Battery cover - Eng 8 - - Eng 9 -...
  • Page 6: Loading The Batteries

    LOADING THE BATTERIES LOADING THE BATTERIES (Batteries supplied with the unit should be loaded in compartment before you use Close the battery cover. the blood pressure monitor.) Open the cover of battery compartment. Pressing the hook down, pull the cover toward you to open. Fitting the lugs of the cover at the mating recesses of the 4 “AA”...
  • Page 7: Measuring Your Blood Pressure

    MEASURING YOUR BLOOD PRESSURE MEASURING YOUR BLOOD PRESSURE ATTACHING THE CUFF Pull the end of the cuff outwards so that the cuff is Before applying your blood pressure cuff, be sure you have selected the snug around your arm and appropriate size cuff: then secure the end to the Cuff (model: SCN-003) fi...
  • Page 8 MEASURING YOUR BLOOD PRESSURE MEASURING YOUR BLOOD PRESSURE Air hose socket is displayed soon after Plug the air hose pressurization is complete, and connector into the main measurement begins automatically. * If the unit judges that pressurization unit. is insuffi cient, it automatically repressurizes.
  • Page 9: Tips For Obtaining Accurate Measurements

    TIPS FOR OBTAINING ACCURATE MEASUREMENTS MEASURING YOUR BLOOD PRESSURE Your blood pressure varies according to your posture, the time of day and a range of [Manual pressurization] other factors. Ideally, you should measure your blood pressure in the same posture •...
  • Page 10: Calling Up The Data Stored In Memory

    CALLING UP THE DATA STORED IN MEMORY CALLING UP THE DATA STORED IN MEMORY • 90 measurement results can be stored in the memory. • Except for the case where the unit is engaged in measurement, press “MEMORY” switch to call up the values (measurement results) stored in memory to the display.
  • Page 11: Key To Display Icons

    KEY TO DISPLAY ICONS ABOUT “BLOOD PRESSURE” What is blood pressure? The heart is a pump that circulates blood throughout your body. Blood is pumped from the heart at a constant pressure into arteries. This pressure is called the arterial blood pressure and represents, in general terms, your blood pressure. Blood pressure is indicated by several kinds of pressures, including the systolic pressure that occurs when the heart pumps blood, and the diastolic pressure that occurs when blood returns to the heart.
  • Page 12: Blood Pressure Q&A

    BLOOD PRESSURE Q&A BEFORE REQUESTING REPAIRS OR TESTING Make sure to check the following before sending your blood pressure monitor away Why is the blood pressure measured at home different from that measured by the to be tested or repaired. physician or at a hospital? Problem Checks...
  • Page 13: Specifications

    SPECIFICATIONS Model Number: CH-452 Measurement system: Oscillometric method Measurement Localization Upper Arm Cuff: Soft cuff Arm circumference range: 22.0 to 32.0 cm Pressure 0 to 280 mmHg Measurement range: Pulse 40 to 180 pulse/min Pressure ±3 mmHg Accuracy: Pulse ±5% of reading Pressure 3 digits Pulse...
  • Page 14 CITIZEN is a registered trade mark of Citizen Holdings Co., Ltd., Japan. Design and Specification are subject to change without notice.

Table of Contents