CONVERSION OF GAS
Your cooker is designed to work with natural
gas, and is convertible for use with propane
or butane.
The LPG conversion kit is available from your
Service Force Centre and must be fitted by a
Registered engineer/ competent person.
For changing the gas type it is necessary to:
replace the nozzles (hob, oven and grill);
•
adjust the minimum level (hob and
•
oven);
Normal
Burner
power
(kW)
2.60
RAPID
2.50
2.50
2.00
SEMI-RAPID
2.00
2.00
1.00
AUXILIARY
1.00
1.00
3.20
OVEN
3.20
3.20
2.50
GRILL
2.50
2.50
22
SPECIFICATION NOZZLES
Table no.1
(Cat : II
Simmer
By-pass
power
(mm)
(kW)
0.72
0.42
0.43
0.32
0.35
0.29
1.00
0.46
-
-
adjust the primary air (oven and grill);
•
check the gas connection;
•
Stick the label supplied with the
replacement nozzles (from the Service
Force Centre) corresponding to the gas
type utilized.
)
2H3+
Pressure
Gas Type
(mbar)
Natural Gas
20
Butane
28-30
Propane
37
Natural Gas
20
Butane
28-30
Propane
37
Natural Gas
20
Butane
28-30
Propane
37
Natural Gas
20
Butane
28-30
37
Propane
Natural Gas
20
Butane
28-30
Propane
37
Nozzle
Cons
diameter
(mm)
g/h
1.13
-
0,77
181,78
0,77
178,53
0.96
-
0,71
145,43
0,71
142,83
0.70
-
0,50
72,71
0,50
71,41
1.30
-
0,88
232,68
0,88
228,52
1,15
-
0,80
181,78
0,80
178,53