INSTALLATION

Location of appliance
The appliance must not be installed in a bed-
sitting room of volume less than 20m
bathroom or shower room. It is essential that the
appliance is positioned as in the enclosed figure
i.e. shelves, wall cabinets and cooker hoods
must be fitted a minimum of 690mm directly
above the hob and 400mm above the hob when
fitted in line with the outside of the appliance. If
the units are intended to be fitted adjacent to the
appliance but less than 400mm above the hob,
then a minimum space of 100mm must be
maintained between the sides of the unit and
the appliance (see fig).
If fitted next to or between two base units a
minimum space of 1mm must be left between
each unit and the sides of the appliance. The
levelling feet fitted to the appliance will
achieve a nominal height to hob of
900mm+10mm.
The appliance must be installed in
accordance with EN 1116-1995, regarding
the depth of the superior furniture.
C
G
2 1 3
4 5 67 8
L.P.G. cookers or ovens MUST NOT
be installed below ground level, i.e. in a
basement, or aboard any boat, yacht or
other vessel.
or in a
3
max 400
100
min 600
less than
C
G
2 1 3
4 5
67 8
min 570
The cooking appliance must be
fitted with a stability chain firmly secured
to the wall.
Firmly fix
chain to rear
of cooker
Stability
chain

Ventilation

The room containing the cooker should have an
air supply in accordance with B.S. 5440: Part 2:
Current Editions.
The following requirements for ventilation
must be met.
The cooker should not be installed in a bed
sitting room with a volume of less than 20m
it is installed in a room of volume less 5m
air vent of effective area of 110cm
if it is installed in a room of volume between
5m
and 10m
3
3
50cm
is required, while if the volume exceeds
2
11m
no air vent is required. However, if the
3
400
room has a door, which opens directly to the
outside, no air vent is required even when the
volume is between 5m
If there are other fuels burning appliances in
the same room, B.S. 5440: Part. 2: Current
Editions should be consulted to determine
the requisite air vent requirements.
Stability
hook
Chain to be as
practicable
is required;
2
, an air vent of effective area
and 11m
.
3
3
short as
, if
3
an
3