Husqvarna Automower 230 ACX Operator's Manual page 54

Husqvarna automower
Hide thumbs Also See for Automower 230 ACX:
Table of Contents

Advertisement

Corridor width (3-2-3)
The Corridor width setting defines the distances
from the mower's path to the boundary wire or
the guide wire when following these to/from the
charging station. The area beside the wires used
by the mower is called the Corridor.
A low corridor width value represents a narrow
corridor while a high value represents a wide
corridor. With a narrow corridor Automower
always runs close to the boundary wire
respective guide wire. With a wide corridor
Automower
varies how it runs, i.e. close to and
®
further from the boundary wire respective guide wire.
Corridor width is a relative distance and is stated
on a scale from 0 to 20. The lower the Corridor
width value the closer Automower
boundary wire and/or guide wire.
Different corridor widths can be set for the
boundary wire, guide 1 and on guide 2. The
default setting on Automower
10 for both the boundary wire and guide wires.
The higher the stated Corridor width value, the
less risk there is of tracks forming. However, a
high corridor value means that Automower
find it difficult to enter passages.
A garden with large open areas should have a
wide Corridor, i.e. a high Corridor width value.
A garden with passages should have a narrow
Corridor, i.e. a low value for the Corridor width.
When the value is set to 0 for the Corridor width,
Automower
®
will run along the boundary wire,
which means it will run with half the mower inside
the loop and half the mower outside. As there are
often flower beds, hedges and walls along with
the boundary wire Corridor width 0 is not
normally recommended. Should you still like to
state this value, the boundary wire must lay 16"
(40 cm) from solid objects instead of the normal
14" (35 cm).
IMPORTANT INFORMATION
The distance at which the mower follows the
boundary wire varies depending on how the
working area appears. You should perform
some tests to find the highest possible
Corridor width. Use the Test IN (3-2-4)
function to try different values.
54 - English
6. MENU FUNCTIONS
®
follows the
®
®
is set to a value of
®
may
Follow loop out
Follow loop in
Corridor width
Test IN
Test OUT
3-2-3
Corridor
Boundary corridor
Guide 1 corridor
Guide 2 corridor

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Automower 220 ac

Table of Contents