3. BATTERY
CONNECTIONS
(for electric
starter)
Use a 12 volt battery with an ampere-hour
rating of at least 18 AH.
Connect the battery positive (+) cable to the starter solenoid terminal as
shown.
Connect the battery negative (-1 cable to an engine mounting
bolt, frame
bolt, or other good engine ground connection.
Check the battery cable connections
to be sure the cables are secured and
free of corrosion.
Remove any corrosion and coat the terminals and cable
ends with grease.
m
l
The battery
gives off explosive
gases; keep sparks,
flames
and cigaret-
tes away.
Provide adequate
ventilation
when charging
or using batteries
in an enclosed
space.
l
The battery
contains
sulfuric
-a&d (electrolyte).
Contact
with
skin or
eyes
may cause
severe
burns.
Wear
protective
clothing
and a face
shield.
- If electrolyte
gets on your skin, flush
with
water.
- If electrolyte
gets in your' eyes,
flush
with
water
for at least
15
minutes
and call a physician
immediately.
l
Electrolyte
is poisonous.
- If swallowed,
drink large quantities
of water
or milk and follow
with
milk of magnesia
or vegetable
oil and call a physician.
.
KEEP OUT OF REACH OF CHILDREN.
CAUTION:
l
Use only distilled
water in the battery.
Tap water will shorten
the service
life of the battery.
l
Filling the battery
above the UPPER LEVEL line may cause the electrolyte
to overflow,
resulting
in corrosion
to engine or nearby
parts. Immediate-
ly wash
off any spilled
electrolyte.
l
Do not connect
the battery
in reverse
polarity
as this will short circuit
the battery
charging
system
and trip the circuit
breaker.
NEGATIVE (-1
.'
BATTERY CABLE
STARTER
SOLENOID
SITIVE (+) BATTERY CABLE
5