Flush Wall Installation
FINISHED WALL
3" OF NON-COMBUSTIBLE MATERIAL
NONCOMBUSTIBLE MATERIAL
(INSTALLATION IS OPTIONAL)
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
Combustible Surround Installation
26408-0-1009
Figure 12
Figure 13
Attention: Cold climate installation recommendation: When
installing this unit against a non-insulated exterior wall, it is
recommended that the outer walls be insulated to conform
to applicable insulation codes.
Vent Runs (Figures 14, 15, 16, 17, and 18)
In planning the installation for the fireplace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for the
appliance and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry
blocks.) These supports must be positioned so they contact
all four (4) perimeter edges on the bottom of the unit.
Note: Fireplace must be mounted above floor surfaces. Doors will
not operate properly if fireplace rests below room flooring.
vERTICAL, 90° ELBOW WITH HORIzONTAL
TERMINATION
Lp and Nat models
Figure 14