Be CertAIn to shut off the Plasma Cutter, and disconnect it from power and air before adjusting,
cleaning, or repairing the unit. A technician should discharge all capacitors before performing
any internal procedures.
FAn runs When sWItChed On But ArC WIll nOt IgnIte
AIr Pressure
tOO hIgh
Adjust the Air regulator to
deliver only 60-80 PsI to
the Cutter.
lOOse
COnneCtIOns
shut off switch, if not off already, and
tighten connections.
If connections do not tighten properly,
contact a qualified technician.
If the steps above do not solve the problem or if the repairs involved are
Page 18

trOuBleshOOtIng

the Air pressure may be too high or too
low. Check the Air Pressure setting on
the regulator's gauge.
make sure that all air and
electrical connections are
tight.
too complex, contact a qualified technician.
For technical questions, please call 1-800-444-3353.
ImPOrtAnt!
AIr Pressure
COrreCt
disconnect the torch Cables.
disassemble the torch assembly and in-
spect all internal components.
replace any damaged or missing compo-
nents and reassemble carefully, following
the directions on page 9.
AIr Pressure
tOO lOW
a. verify that the compres-
sor is delivering at least
3.5 CFm @ 60 PsI to the
tool.
b. the regulator on the
unit must be set to at
least 60 PsI.
tIght
COnneCtIOns