Specifications; Duty Cycle - Chicago Electric 95136 Set Up And Operating Instructions Manual

Inverter air plasma cutter
Table of Contents

Advertisement

sPeCIFICAtIOns

Rated Input
Rated Duty Cycle
Air Requirement
Power Switch
Weight
Cutting Current
Cutting Thickness
Arc Striking System Pilot Arc
Unit Size

duty Cycle

Duty Cycle is the equipment
specification which defines the number
of minutes within a 10 minute period that
a piece of equipment can safely operate.
This plasma cutter has a 60% duty
cycle at 40 Amps, which means that it
may be used only 6 minutes at 40 Amps
out of any 10 minute period, and must be
rested the remaining 4 minutes.
CAutIOn: Failure to observe the duty cycle
limitations of this Plasma Cutter can
easily damage this equipment, and will
void the warranty.
Page 8
240 V~, 50/60 Hz, 19.2 A
60% @ 40 A;
80% @ 34.6 A;
100% @ 31 A
60-80 PSI @ 3.5 CFM
Rocker Type
49.6 lb.
15 - 40 Amps
½" mild steel Maximum
20" L x 8-1/8" W x 14-3/8" H
For technical questions, please call 1-800-444-3353.
unPACKIng
When unpacking, check to make sure the
following parts are included.
Inverter Plasma Cutter tool with
Cutting Torch with Power Cord
Ground Cable with Clamp
If any parts are missing or broken, please call
Harbor Freight Tools at the number on the cover
of this manual.
Preparing Your Work Area
1.
You must have a sturdy work table that
is open below the area you are cutting.
Molten slag will be blown through the
work metal, and must be able to fall
away freely.
2.
Your work table must allow the work
metal to be firmly clamped to prevent it
accidentally falling or moving.
3.
The floor and surrounding area of your
work site must not be flammable. A
clean cement floor is recommended. The
cutting process will eject molten metal
slag onto the floor, and it will scatter for
8-10 feet or more in any direction. Have
an adequate fire extinguisher available if
needed.