Electrical
connection
For the authorised
service employee
Installation must be carried out by an authorised
service employee. A 16A circuit breaker is required for
the connection. The appliance has been designed to
be used with 220 240V mains current.
If the voltage drops below 180 V, then the electrical
igniter system will not function.
All warranty rights will be invalidated if damage occurs
due to incorrect connection and installation.
The device must be connected according to the
information on the identification plate.
Connect the appliance only to an electrical
connection that is in compliance with the regulations.
Once the appliance has been connected, it must be
possible to reach the connection point easily so that it
can be disconnected.
A multi pole separator system must be provided.
The use of extension cables and multi socket
adapters is forbidden.
This appliance must be operated with an earthed
connection to provide adequate electrical safety. If the
appliance is not earthed in accordance with
regulations, then protection against hazards in the
electrical system cannot be guaranteed.
H 05 W F or an equivalent type of cable should be
used to connect the appliance.
11