SERVICING

A: Removal Of Hob Top
1. Remove the panstands and each burner cap and
crown.
2. Lift the hob from off the working top.
3. Remove the two self tapping screws from each
burner and the two fixing screws on the right hand
side of the hob.
B: Removal Of the Hob Taps
(Isolate Electric Supply)
1. Follow the procedures in Section A.
2. With the aid of a 7mm spanner remove the
clamping bolt from the fixing clamp.
3. Loosen the pipe connection nut from the gas tap
with the aid of a 16mm spanner. Remove fixing
clamps.
4. Reassemble in reverse order and carry out leak
test.
C: Removal Of Mains Terminal Block
(Isolate Electric Supply)
1. Follow the procedures in Section A.
2. Disconnect supply flex connections from terminal
block.
3. From the underside of the hob remove 1 self
tapping screw from the terminal block.
4. Reassemble in reverse order.

CONVERT FROM NATURAL GAS TO LPG

It is important to note that this model is designed for
use with natural gas but can be converted for use
with butane or propane gas providing the correct
injectors are fitted. The gas rate is adjusted to suit.
METHOD
Ensure that the gas taps are in the 'OFF' position
Isolate the appliance from the electricity supply
Remove all pan supports, burner caps, rings,
crowns and control knobs.
With the aid of a 7mm box spanner the burner
injectors can then be unscrewed and replaced by
the appropriate LPG injectors.
20
D: Removal Of Burner
1. Follow the procedures in Section A.
2. With the aid a 12mm spanner loosen off the pipe
connection nut.
3. From the underside of the hob remove 2 self
tapping screws from the burner body.
4. Reassemble in reverse order and carry out leak
test.
E: Removal Of Ignitor Unit
(Isolate Electric Supply)
1. Follow the procedures in Section A.
2. Disconnect H.T. leads and the ignition switches
connector.
3. With the aid of a pair of thin nose pliers, pull the
spring clip sidewards off of the underside of the
ignitor.
4. Reassemble in reverse order and check with
wiring diagram for correct reconnection.
F: Remove Taps Ignition Switches
(Isolate Electric Supply)
1. Follow the procedures in Section A.
2. Disconnect the switches connector from the
ignitor unit and remove the supply cables pulling
the tabs connection off.
3. Reassemble in reverse order and check with
wiring diagram for correct reconnection.
TO ADJUST THE GAS RATE
With the aid of a thin bladed screwdriver completely
tighten down the by pass adjustment screw, which is
located down the centre of the gas tap control shaft.
Upon completion stick the replacement rating plate
on the under side of the hob.
IMPORTANT
The replacement/conversion of the gas hob
should only be undertaken by a competent
person