OVERALL DIMENSIONS
Width:
580 mm.
Depth:
510 mm.
Thickness: 40 mm.
Height:
88 mm.
Weight:
11 Kg.
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.
This appliance complies with the EEC Directive No 89/336, concerning suppression of radio electrical
interference.
Ignition HT Spark
Spark Generator
Spark Gap
Rear Left Burner (semi rapid)
Heat Input
Front Left Burner (rapid)
Heat Input
2.9 kW Natural Gas (9895 BTU/HR)
2.7 kW L.P.G. (9212 BTU/HR)
Burner
Auxiliary
Semi-rapid
Rapid
Aeration adjustement none
Ispra Control's BF 50046 - 240V 0.6 YA T 120
Fixed
1.9 kW (6483 BTU/HR)
BURNER
POSITION
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
m
NOZZLE REFERENCE
1/100 mm
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
1/100 mm
Dia. Tap By-pass
1/100 mm
28
32
40
CUT OUT DIMENSIONS
Width:
550 mm.
Depth:
470 mm.
Rear Right Burner (semi rapid)
Heat Input
Front Right Burner (auxiliary)
Heat Input
RAPID
SEMI-RAPID
(large)
(medium)
MAX
MIN
MAX
kW
2.9
0.65
1.9
3
/h
0.276
0.062
0.181
119
Adjust.
96
kW
2.7
0.65
1.9
g/h
195
46.8
137
86
40
71
Tap colour
Red/Red
Blue/Blue
Black/Black
1.9 kW (6483 BTU/HR)
1.0 kW (3412 BTU/HR)
AUXILIARY
(small)
MIN
MAX
MIN
0.45
1.0
0.33
0.043
0.095
0.031
Adjust.
70
Adjust.
0.45
1.0
0.33
32.4
72
23.8
32
50
28
11