SECTION 2: GAS REQUIREMENTS

NATURAL GAS REQUIREMENTS -

Inlet Connection: 1/2" NP with 3/8" NPT reducer adapter.
Supply Pressure: 6" to 14" W.C.
Manifold Pressure: 5" W.C.

PROPANE GAS REQUIREMENTS -

Inlet Connection: 1/2" NP with 3/8" NPT reducer adapter.
Supply Pressure: 11" to 14" W.C.
Manifold Pressure: 10" W.C.
L
IMPORTANT: A manual gas shut off valve must be installed external to the appliance, in
!
a location accessible with the unit installed in the enclosure. Make sure the valve is turned
off prior to connecting the appliance.
L
IMPORTANT: Un robinet manuel d'isolement doit étre installé à l'extérieur de l'appareil, dans
!
un emplacement accessible avec l'unité installée dans la module. Assurez-vous que le robinet est
fermé avant de brancher l'appareil.

PROPANE HOOK-UP

Tank Gas Regulator

GAS CONSUMPTION

The total gas consumption of the Thermador
follows:
®
Char Glo
CGB30RCULP =
CGB36RU =
CGB48RU = 109,000
CGB48RSBU = 107,000
LP Gas Tank
®
barbecues with all burners on "HI" is as
52,000
BTU/Hr
77,000
BTU/Hr
BTU/Hr
BTU/H