SECTION 2: GAS REQUIREMENTS

NATURAL GAS REQUIREMENTS -

Inlet Connection: 1/2" NP with 3/8" NPT reducer adapter.
Supply Pressure: 6" to 14" W.C.
Manifold Pressure: 5" W.C.

PROPANE GAS REQUIREMENTS -

Inlet Connection: 1/2" NP with 3/8" NPT reducer adapter.
Supply Pressure: 11" to 14" W.C.
Manifold Pressure: 10" W.C.
L
IMPORTANT: A manual gas shut off valve must be installed external to the appliance, in
!
a location accessible with the unit installed in the enclosure. Make sure the valve is turned
off prior to connecting the appliance.
L
IMPORTANT: Un robinet manuel d'isolement doit étre installé à l'extérieur de l'appareil, dans
!
un emplacement accessible avec l'unité installée dans la module. Assurez-vous que le robinet est
fermé avant de brancher l'appareil.
FIGURE 1 – PROPANE HOOK-UP
Coupling 1/2" NPT fitting
threading compound on
these threads must be
L.P. Regulator hose
resistant to LP gas
assembly 10" W.C.
CGBD30RX Shown

GAS CONSUMPTION

The total gas consumption of the Thermador
Bottom of
unit
Type 1 Regulator
Regulator Adapter
Main
Valve
L.P. Tank
©
(Type 1)
®
Char Glo
CGBD30RX
=
CGBD36RX
=
CGBD48RSBX
=
CGBD48RX
=
FIGURE 2 – NATURAL GAS HOOK-UP
Regulator 5.0" W.C.
Threading compound must
be resistant to L.P. gas
CGBD30RX Shown
®
barbecues with all burners on "HI" is as follows:
52,000
BTU/HR
77,000
BTU/HR
107,000
BTU/HR
109,000
BTU/HR
Page 3
1/2" NPT
Close Nipple
Adapter 1/2" NPT
to 3/8" flare fitting
Installer supplied
shut-off Valve must
be easily accessible