10. FAST - program
Should you require large quantities of coffee at set times, you can
program up to 3 time periods during which the machine will main-
tain the maximum storage volume of 4 litres - irrespective of the
currently selected program. If the storage volume drops below 3 lit-
res, an extra litre of coffee is filtered after a certain interval. If the
storage volume falls below 2 litres during this time interval, an extra
2 litres of coffee are prepared immediately.
b
If your peak requirement periods are e.g. between 09:30 -
10:30 and 12:30 - 13:30, you can program these periods
(see 12.11 „Fast - Program", page 20) as automatic time 1
and automatic time 2.
Irrespective of the currently selected program (0 - 0.5 - 1 - 2 - 3 -
4 - Ltr.), the machine will automatically begin the FAST - program
at 09:30 and 12:30.
The display (1) shows the following message:
FAST
4 LTR
The program ends automatically at 10:30 and 13:30 respectively
and the machine changes back to the selected program with the
corresponding display reading.
Please note, that while forced drainage of the storage urn is activa-
ted (see 6. „Automatic storage draining", page 11) the programmed
FAST times will be deactivated! The machine only brews either one
or two litres for the emptied storage urn.

11. Timer

The machine is equipped with an automatic time switch.
Details on the programming of this switch can be found in the sec-
tion 12.10 „Timer", page 20.
The following functions can be switched with this timer:
b
FAST - program ON/OFF

Cleaning time

b
b
Switching ON/OFF with timer see 11.3
b
Automatic starting with filter see 11.4

11.1 FAST - program ON / OFF

b
Please refer to section 10. „FAST - program", page 15 for
automatic operation, during which the machine will automa-
tically maintain the maximum storage volume of coffee.
For switching the FAST - program ON or OFF, see 12.11
„FAST - program", page 20.
11.2 Cleaning time
To achieve a regular cleaning cycle, a set cleaning time can
b
be programmed. When this time is reached, the display indi-
cates the cleaning message (see 8.2.1 „Cleaning time",
page 13).

11.3 Switching ON / off with timer

b
Automatic switching ON and OFF of the machine at set
times.
One automatic switch-on time and one switch-off time can
be programmed.
Operating Instructions Pages 9 - 23
S : 1,8 Ltr.
see 11.1
see 11.2
If the machine is required to switch on and off automatical-
ly, then the timer must be set to on (see 12.10 „Timer
OFF/on setting", page 20).
After a completed cleaning process (see 8.2.3 „Starting
automatic cleaning", pages 13-14) or after a manual swit-
ching off of the machine (see 9. "Switching machine off",
page 14), the key-operated switch (9) must be in the
„Operator" position.
11.3.1 Time switch activated
b
Switch-on time: While the machine is switched off, the dis-
play (1) shows the following message between the switch-
off time and the following switch-on time:
ON AT :
At the pre-selected time, the machine switches itself on and
heats up. This is followed by the automatic pre-warming
program.
If a filtering program (storage volume) is stored, the machi-
ne will proceed to prepare the required volume of coffee.
If the switched off machine is set to start automatically, as descri-
bed above, it can still be switched on manually at any time if, for
example, this should occasionally be required.
b
Turn the key-operated switch (9) to the »Manager« position
(key No. 2), or from the „Operator" position to „0 / OFF" and
back to „Operator" within 5 seconds.
The machine switches on and starts operation.
b
Switch-off time: During daily operation, between switching
on and switching off the machine, the display shows the fol-
lowing information:
BREWING
OFF AT :
This message is temporarily deleted if other displays are
required, such as CUP COFFEE, JUG COFFEE, WATER
etc., or NO WATER/PRESSURE, PLEASE WAIT, BOILER-
TEMPERATURE etc.
At the pre-selected time, the machine switches itself off
automatically. The following information is displayed:
ON AT :
Please note that in the case of programmed switching on (see 11.3
„Timer", Page 15) any coffee left in the storage urn is automatical-
ly discharged, so that the machine is ready for operation as soon
as it is automatically switched on.
It is advisable that at switch-off time the machine has been cleaned.
See 8. „Cleaning and care", pages 13-14.

11.4 Automatic starting with timer

The timer can be used to switch the machine on automatically at a
set time (usually at the start of business in the morning) so that the
program selected on the previous day is immediately started. This
setting ensures that a desired volume of coffee is available at a de-
sired time without the need for personnel.
b
Switch the timer to „ON" and set the starting time (see 12.10
„Timer OFF/ON setting", page 20).
b
Select the desired program (see 12.2 „Selecting filter pro-
gram and storage volume", page 17) after cleaning has star-
ted and the program is running (see 8.2.3 „Starting auto-
matic cleaning", page 13-14).
Please note! Program selection is only possible during
the active cleaning program!
c2000
TU
07:30
S : 1,8 Ltr.
TU
18.00
c2000
WE
07.30