Know Your Switch Plate - Nilfisk-Advance APC 328 Information & Operating Instructions

All purpose cleaner 220-240v eu & uk
Hide thumbs Also See for APC 328:
Table of Contents

Advertisement

KNOW YOUR SWITCH PLATE

Vacuum Switch (1): turns on the vacuum motor.
Chemical Valve (2): switches between the two chemical containers. When the selector is pointed
straight down, the valve is off and neither chemical is selected. When the selector is pointed directly
towards one or the other symbols, that chemical is selected.
Solution Pump Switch (3): turns on the solution pump.
Quick Connect (4): this is where solution comes out of the machine and the attachment point for
the solution hose.
METERING TIPS
The chemical metering tips allow you to select the ratio of chemical to water, as the water flows out of
the machine. Insert the correct metering tip for the desired mixture into the chemical siphon tube.
COLOR
HOLE SIZE
Orange
Pink
Dark Green
Yellow
Light Blue
Burgandy
Black
1
I
4
METERING TIPS
MIX RATION
0.007
1 to 128
0.012
1 to 64
0.014
1 to 50
0.016
1 to 32
0.020
1 to 20
0.022
1 to 15
0.048
1 to 5
2
O
O
3
FLOW RATE
7,81 ml per 1 l
19,53 ml per 1 l
23,44 ml per 1 l
39,06 ml per 1 l
46,87 ml per 1 l
70,33 ml per 1 l
156,27 ml per 1 l