Clearing Jams - Central Pneumatic 91053 Assembly And Operating Instructions Manual

Framing nailer 34 degree & 28 degree magazine angles contractor series
Table of Contents

Advertisement

Anytime any maintenance or repairs are done (including clearing jams),
1.
Disconnect the Nailer from the air hose.
2.
Empty the Magazine (74) completely.
3.
Attempt to fire the Nailer into a piece of scrap wood to ensure that it is discon-
nected and is incapable of firing any nails.
1.
Occasionally a Nail may become jammed in the firing mechanism of the Nailer,
making the tool inoperative.
2.
To remove a jammed nail, disconnect the Nailer from its compressed air supply.
Slide the Tab (64) back and empty the Magazine (74) completely of Nails. At-
tempt to fire the Nailer into a piece of scrap wood to ensure it is disconnected
and is incapable of firing any nails.
3.
Use a pair of needle nose pliers (not included) to remove the jammed nail (usu-
ally from the Upper Safety (28) and/or Lower Safety (32) areas). While holding
the Tab back, carefully press the Latch. BE CAREFUL. When you press the
Latch (78), the Tab (64) will spring forward with force. Slowly and cautiously allow
the tab to slide forward.
4.
Reconnect the air supply hose to the tool.
5.
Press the Lower Safety (32) of the Nailer against a piece of scrap wood.
6.
Test fire the Nailer several times, checking for proper operation.
7.
If the Nailer is properly firing, you can continue to use the Nailer. Disconnect the
air supply to the Nailer, and reload the Nails. Then, reconnect the air supply and
continue working.
8.
When finished working, Disconnect the air supply. Remove the Nails. Then,
store the Nailer and nails in a location out of children's reach.