Spreading chart
Table of Contents

Advertisement

Handle Assembly
5.
Position spreader as shown.
Attach T-handle assembly loosely
to cross-bar of frame (39) using
(1) bolt [52] & nut [53].
NOTE: Model 58-22 has a black
plastic hopper
6.
Secure the handle braces [43] to
inside of frame using (2) bolts
[51] & nuts [53].
7.
Check for proper alignment &
then tighten all nuts and bolts at
this time.
New Linkage Adjustment Procedure
1.
Set regulator dial to 1.
2.
Set lever completely to off position.
3.
Attach cable clamp (59) to ground prop with 1
bolt and nut and finger tighten.
4.
Route cable through clamp, then through swivel and
then tighten the cable clamp bolt just enough to allow
the cable to slide back and forth easily.
5.
Adjust sheath on cable so there is a 1/8" inch of
control wire that is visible between the sheath and the edge of the rate gate linkage.
6.
Tighten the cable clamp bolt to secure the sheath.
7.
Tighten the screw on the cable fastener to anchor the wire, making sure that the
rate gate linkage is pushed up against the dial.
8.
Trim excess wire behind cable fastener connector when finished (if necessary).
Dial Setting Information
The RATE DIAL has 9 numbers with 10 stops between each num-
ber, for accurate control of
the spreading rate.
The dial is set with only a turn. It will automatically lock into the set
position. LINE UP THE DIAL NUMBER WITH THE DIAL INDICATOR.
1
/
"
4
3
Granule Size - Dial Setting Guide
Dial settings are approximate only.
Product
Fine Pellets
Mixed Fine Pellets
Small Pellets
Nitrogen Pellets Med.
Med. Pellets & Granules
Med. Pellets
Large Heavy Pellets

Read Before Using

The Accuway has two ramps. A front side and a back side ramp.
Viewed from operators position.
The front side ramp
2
is used to shift the spread pattern to the right.
The back side ramp
4
is used to shift the spread pattern to the left.
NEVER, NEVER, NEVER USE ACCUWAY FRONT AND REAR RAMPS TO
SPLIT THE PRODUCT FLOW. Use only the front side or the back side.
With proper adjustment you should be able to achieve a balanced
spread pattern.
First - set the spread rate dial
Now you are ready to balance the spread pattern.
2
A
Note the relationship of the rate gate
opening to the front side of the ramp.
Lbs. per 1000 Sq. Ft.
Full Rate
Half Rate
1
3.6
3.1
2
4.0
3.5
3
4.2
3.7
2
3.7
3.2
4
4.7
4.1
6
5.2
4.5
2
3
2.2
4
4.2
3.7
6
4.5
4
1
3.5
3
2
4.2
3.7
3
4.7
4
2
3.5
3
4
4.2
3.8
6
5.2
4.5
2
3.5
3
4
4.2
3.8
6
5.2
4.5
2
3.8
3.3
4
4.9
4.1
6
5.9
4.9
3
.
1
B
Note the relationship of the rate gate
opening to the back side of the ramp.