However, it does not sterilize or destroy
microorganisms. You may need to purchase a
water purifying system to do that. In order for the
ice-maker to operate properly, a water pressure of
138~862 Kpa is required.
Under normal conditions, a 170 cc (5.75 oz.) cup
can be filled in 10 seconds. If the Refrigerator
is installed in an area with low water pressure
(below 138Kpa), you can install a booster pump to
compensate for the low pressure.
Make sure the water storage tank inside the
Refrigerator is properly filled. To do this, press the
water dispenser lever until the water runs from the
water outlet.
Water line installation kits are available at extra cost
from your dealer.
We recommend using a water supply kit that
contains copper tubing.
Check the accessory list below.
Hex wrench
Compression fitting
Connecting to the water supply line
1. First, shut off the main water supply line and turn
the ice-maker off.
2. Locate the nearest cold water drinking line.
3. After connecting the water supply with water
filter, turn on water supply and Flush 3L through
filter before use (flush approximately 6 minutes).
Cold Water Line
Shut off valve

INSTAllING THE WATER lINE

Connecting the water line to the
Refrigerator.
Fastener
Compression nut
Pipe clamp
Water line
installation
kit
There are several items that you need to purchase to
complete this connection. You may find these items
sold as a kit at your local hardware store.
6.35mm compression
nut
plastic tubing
Plastic tubing (A)
(Supplied)
Ferrule (Not
supplied)
Copper tubing
(Not supplied)
Household water line
1. Slip the compression nut through the supplied
plastic tubing(A).
2. Tighten the compression nut (A) onto the 6.35mm
compression fitting.
- If you are using copper tubing, slip the
compression nut (B)(not included) and ferrule
(not included) on copper tubing (not included) as
shown.
- If you are using plastic tubing (B), insert the
molded end(Bulb) of the plastic tubing (B)into
the compression fitting. Do not use without the
molded end(Bulb) of the plastic tubing (B).
3. Tighten the compression nut (B)onto the
compression fitting. Do not over-tighten the
compression nut (B).
4. Turn water on and check for any leakage.
Only connect the water line to a drinkable water
source. If you have to repair or disassemble the
water line, cut off 6.35mm of the plastic tubing to
make sure you get a snug, leak-free connection.
copper tubing
ferrule
Refrigerator
Compression
nut (A) (1/4")
(Supplied)
Compression
fitting (Supplied)
Molded
end(bulb)
Compression
nut (b) (1/4")
(Not supplied)
Plastic tubing (b)
or
(Not supplied)
setting up _11