11. TROUBLESHOOTING

When generator engine fails to start after several attempts, or if no electricity is
available at the output socket, check the following chart. If your generator still fails
to start or generate electricity, contact your nearest
service center for further information or corrective procedures.
When Engine Fails to Start :
Check if choke lever is in its proper
position.
Check if fuel cock is open.
Check fuel level.
Check if engine switch is in OFF.
Check to make sure generator is not
connected to an appliance.
Check spark plug for loose spark plug
cap.
Check spark plug for contamination.
When No Electricity Is Generated at Receptacle :
Check to make sure no-fuse breaker is
in the "ON" position.
Check AC and DC terminals for loose
connection.
Check to see if engine starting was
attempted with appliances already con-
nected to generator.
Makita factory or authorized
Set the choke lever to "CLOSE" posi-
tion.
If closed, open fuel cock.
If empty, refill fuel tank making sure not
to overfill.
Turn engine switch to ON.
If connected, turn off the power switch
on the connected appliance and unplug.
If loose, push spark plug cap back into
place.
Remove spark plug and clean electrode.
After making sure that the total wattage
of the electrical appliance is within per-
missible limits and there are no defects
in the appliance, turn the no-fuse break-
er to the "ON" position.
If breakers continue to actuate, consult
your nearest servicing dealer.
Secure connection if necessary.
Turn off switch on the appliance, and
disconnect cable from receptacle.
Reconnect after generator has been
started properly.