9.7.

Blue Focus / Gamma Adjustment

Preparation
Picture Menu : Dynamic
C Temp : Standard
B-Limit : 255
AI : ON
P-NR : ON
Scan Mode : 100Hz (PAL)
Adjustment
1. Set the White Balance Meter on Screen center.
2. Receive a Window pattern.
3. Set the Sub Contrast and High-B to Max.
4. It pushes and it makes a [HELP] key the project only of BLUE.
5. Adjust Blue Focus VR so that Y is 4.0 ± cd/m
9.8.

White Balance Adjustment

Preparation
Picture Menu : Dynamic
C Temp : Dynamic
High R : 90
AI : ON
High G : 128
P-NR : ON
High B : 90
Scan Mode : 100Hz (PAL)
Low G : 640
Adjustment
1. Set the White Balance Meter on Screen center.
2. Receive a Window pattern.
3. Adjust Sub Bright so that the 6th paragraph shines faintly and the 7th paragraph does to the sinking style.
4. Adjust High R, WB-B-G-ST1, High B, Low R, and Low B to the table value.
WB-B-G-ST1 : 0
2
Sub Bright : 60
WB-B-G-ST1 : 130
27