Installation procedure

1. Check the strength of the installation location.
The wall-hanging bracket weights
approx. 6 kg (13.2 lbs.), a 50-inch
display weights approx. 45 kg (99.2 lbs.),
a 42-inch display weights approx. 30 kg
(66 lbs.). Using the bracket dimensions
shown in the diagram at right, confirm
that the 6 locations for mounting the
bracket to the wall are able to bear the
combined weight. If the wall is not strong
enough, reinforce it.
N o t e
Note
The wall-hanging bracket has 24 installation holes.
If the wall material is not strong enough to install
the display using six installation holes, use some of
the spare holes. However, depending on the wall
material, cracks may develop and attachment
intensity becomes inadequate if the screws are
inserted too close to each other.
2. Install the wall-hanging bracket to the wall.
• Hang the bracket so that the arrow on the bracket points to the right.
• If it is necessary to embed bolts or nuts beforehand because the wall is made of concrete, use
the bracket itself to determine the correct installation hole positions, or use the dimension
diagram to calculate the hole positions. Then embed the M6 bolts or nuts into the holes. Embed
the bolts so that they protrude from the wall by 10 mm (
Installation procedure
1. Insert a bolt into the upper right hole.
2. Use a level to adjust the bracket so that it is parallel to the
ground. Insert bolts into the other 5 holes.
3. Insert and slightly tighten the fixing screw (M5 x 35). Do not
insert the bolt more than 5 mm (
cannot be installed in the correct position if the bolt is over-
tightened.
*
Note: In this case, the wall-hanging bracket fixing screw
(M5 x 135) is not used.
N o t e
Note
Use commercially available bolts which suit the wall materials for installation to the wall.
4
Dimensions of the wall-hanging bracket
(sold separately)
Used for routing wires
behind a wall
Wall installation holes
(6 locations)
13
/
32
13
/
inch). The display
64
19
490 (19
/
)
20
64
25
(
/
)
23
450 (17
/
)
32
32
50
31
(1
/
)
32
30
3
(1
/
)
16
19
inch) to 15 mm (
/
32
Fixing screw
Fixing screw
Units
: mm
(
): inch
20
25
(
/
)
32
15
19
(
/
)
32
inch).