Contrast Adjustment; Adjustment Procedure - Panasonic BT-H1350Y Service Manual

Color video monitor
Table of Contents

Advertisement

6. Disconnect an oscilloscope from
@
and connect
an oscilloscope to emitter of Q1313.
Video Generator
A-P.C.board
VIDEO
Oscilloscope
Monitor TV
Fig. 6
7. Adjust
R1316
(CW
Level) and C1308
to set 3.58
MHz sub carrier at the minimum amplitude.
8. Confirm
that 3.58 MHz
sub carrier portion of the
magenta is less than 100mVp-p as shown in Fig. 7.
CONTRAST
ADJUSTMENT
(A/D/L-P.C. board)
1. EQUIPMENT
TO USED
Oscilloscope
Video Generator
RGB Signal Generator
2. INITIALIZE
CONDITION
ას
ხ""
-<3___-_-___
MმX.
„სო--აა
ს. მა
ო»""""""""""""""""ძ""'
Мах.
Brigätness Cehitrol! va sms makaak aeedaek hard ren Center
3. ADJUSTMENT
PROCEDURE
1. Set the Input Selector Switches to LINE A.
2. Input a Cross
Hatch
pattern signal to VIDEO
input
terminal.
3. Connect an Oscilloscope to emitter of Q1313.
Video Generator
A-P.C. board
01313
00
Monitor TV
Fig. 8
4. Confirm that the A is OV at emitter of 01313.
Fig. 9
5. Disconnect an Oscilloscope from emitter of 01313 and
солпесі ап ОзсШозсоре 10 | ХЕ
спа
А.
ВТ-Н1350Ү
Less than
т "и
100mVp-p
Fig. 7
9. If the amplitude
is more than 100mVp-p repeat the
adjustments described in step 7 through 8.
Monitor TV
Fig. 10
6. Adjust R670 (Sub Contrast) so that the C is 50Vp-p
at
Bed deg as shown in Fig. 11.
Fig. 11
7. Set the Input Selector switches to RGB.
8. Input a Cross Hatch pattern signal (fH = 15.75 kHz)
to RGB inputs terminal.
9. Adjust R3393
(RGB Sub Contrast) so that the C is
БОМр-р а! I:
shown in Fig. 11.
Note:
Be sure to D is 30410Vp-p.
If the D is not 30x 10Vp-p, adjust R3317
(Sub
Brightness).
10. Set the picture to first lightup color (glimmer) by R3317
(Sub Brightness).