I Setting the Vertical Airflow Direction
• Press 5 or 6 to select:-
Cooling Model
COOL / DRY Operation
FAN Operation
AUTO
AUTO
Swing up/down
Swing up/down
Automatically
Automatically
OFF
OFF
Press OFF button to stop
Press OFF button to stop
the swinging of the louver
the swinging of the louver
at the desired airflow
at the desired airflow
direction.
direction.
Heat Pump Model
COOL / DRY Operation
HEAT Operation
AUTO
AUTO
Swing up/down
Swing up/down
Automatically
Automatically
OFF
OFF
Press OFF button to stop
Press OFF button to stop
the swinging of the louver
the swinging of the louver
at the desired airflow
at the desired airflow
direction.
direction.
I Setting the Horizontal Airflow Direction
• Adjust it manually
G Use this air conditioner under the following
conditions:
Cooling Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature
32
23
Minimum Temperature
16
11
Heat Pump Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature-Cooling
32
23
(Maximum Temperature-Heating)
(30)
(-)
Minimum Temperature-Cooling
16
11
(Minimum Temperature-Heating)
(16)
(-)
G Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
G Operation Details
COOL – Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Unit in °C
Low fan speed.
Outdoor
HEAT – Heating Operation
DBT
WBT
(for Heat Pump Model only)
43
26
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
16
11
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
Unit in °C
unit.
Outdoor
FAN – Air Circulation Operation
DBT
WBT
(for Cooling Model only)
43
26
When the room temperature reaches the set
(24)
(18)
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
16
11
2°C below the set temperature.
(-5)
(-6)
(It is useful when using a heater.)