Thermsaver White Cased Oil Boiler Installation And User Manual page 17

White cased oil boiler
Table of Contents

Advertisement

Remove lid
Remove flue ring
Bolt bottom section
Fit Snorkel Tube
Vertical Terminal
INSTALLATION OF VERTICAL FLUE
1. Position boiler and cut hole/s in ceiling and roof.
2. Remove conventional flue ring from top of boiler.
3. Fit Red inner seal and Black outer seal to flue
Remove lid
Fit seals and
lubricant
4. Apply lubricant to the inner and the outer seals.
5. Bolt bottom section of the flue to the boiler
6. Attached snorkel to the flue with the clip.
7. Refit boiler top panel insure the knock out in the
8. Assemble second vertical flue section and any
9. Fit the roof flashing and flue terminal.
Fit Clip
10. Secure the terminal to a roof joist with clamps
11. Fit flue elbows if required and secure vertical
12. Seal around the flue terminal in wall using mastic
13. Remove CF adaptor from burner and discard
14. Fit BF adaptor connect snorkel tube with clip.
Internal View
Remember measure mark ,CHECK then cut.
connectors and extensions if required.
Taking care to only lubricant the lip of the seals.
insuring the square gasket is fitted in between the
boiler and the flue.
panel has been removed.
vertical extension.
provided.
section with the screws provided
NOTE: Expanding foam can be used to
fill/insulate the gap between flue parts and wall.
16