Thermsaver White Cased Oil Boiler Installation And User Manual page 15

White cased oil boiler
Table of Contents

Advertisement

FIT CLIP
FIT LID
3. Fit Red inner seal and Black outer seal to flue
4. Apply lubricant to the inner and outer seals. Taken
5. Bolt bottom section of the flue to the boiler
FIT SNORKEL TUBE
6. Attached snorkel to the flue with the clip.
7. Refit boiler top panel insure the knock out in the
8. Assemble second vertical flue section and any
9. Assemble horizontal section and pass through the
10. Connect vertical and horizontal section together.
11. Secure vertical section with the screws provided.
12. Seal around the flue terminal in wall using mastic.
13. Remove CF adaptor from burner and discard.
14. Fit BF adaptor connect snorkeltube with clip.
NOTE: Expanding foam can be used to fill/insulate
the gap between flue parts and wall.
INTERNAL VIEW
connectors and extensions if required.
care to only lubricant the lip of the seals.
insuring the square gasket is fitted in between the
boiler and the flue.
panel has been removed.
vertical extension.
wall. Making sure that the terminal protudes
through the wall a minimum of 176mm for 80mm
flue and 185mm for 100mm flue.
FLUE EXTENSIONS
Please note a maximum of one kit 6
950mm or 3 x kit 3 300mm extension
can be used on the high level.
Kit 8 45 degree bends must not be used
on high level balanced flue kits.
14
FIT HORIZONTAL SECTION