VERTICAL BALANCED FLUE
FLASHING NOT
SUPPLIED
VERTICAL BALANCED FLUE DIMENSIONS
MINIMUM 600MM
50/70
70/90
90/115
125MM
115/140
140/170
150MM
The vertical flue is telescopic as supplied.
The flue has a range of 1020 - 2400mm
from the top of the boiler to the flashing.
Extension kits of 300 and 950mm
are available.
The maximum vertical length is 4800mm.
Also available are 45 degree bends.
For further information contact our sales office.
N.B. Every 45 degree elbow is equivalent to
500mm of flue.