Thermsaver White Cased Oil Boiler Installation And User Manual page 12

White cased oil boiler
Table of Contents

Advertisement

LOW LEVEL BALANCED FLUE
MODEL
Flue
50/70
3"
70/90
3"
90/115
3"
115/140
4"
140/170
4"
LOW LEVEL BALANCED FLUE SIDE AND REAR ASSEMBLY INSTALLATION
REMOVE CASING LID
REMOVE FOIL
A
B
C
125
176
765
125
176
765
125
176
803
150
185
917
150
185
917
1. Cut hole in wall. Remember measure, mark, CHECK then cut.
2. Remove Conventional Flue ring from top of boiler.
3. Fit Red inner seal and Black out Seal to flue connector and
extension if required.
4. Apply lubricant included in kit. To the inner and outer seal taken
care to only lubricant the lip of the seal.
RETAIN BOLTS FOR
FITTING FLUE
REMOVE FLUE RING
D
A
TERMINAL GUARD
A Terminal Guard must be fitted to low
level Flue Terminal below 2 metres and
where persons or animals could come into
contact with the terminal or if it could be
subject to damage.
D
130
130
130
138
138
FIT SEALS AND
LUBRICATE
11
TEST POINT
FIT SQUARE GASKET