Download Print this page

Maytag MEC7424AB0 Installation Instructions Manual page 5

Electric cooktop

Advertisement

Available languages

Available languages

M<s® E®cff
Co sec!t on
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This cooktop is manufactured with the frame connected
to the
bare ground wire. Connect the cooktop cable to the junction box
through the UL listed or CSA approved conduit connector.
1. Disconnect
power.
2. Remove junction box cover, if present.
3. Connect the flexible cable conduit from the cooktop to the
junction box using a UL listed or CSA approved conduit
connector.
4. Tighten screws on conduit connector if present.
5. See "Electrical Connection
Options" chart to complete
installation for your type of electrical connection.
4-Wire Cable from Power Supply
IMPORTANT:
Use the 4-wire cable from power supply where
local codes do not permit connecting the frame-ground
conductor to the neutral (white) junction box wire:
A
B
C
A. 4-wire cable from power
supply
B. Red wire from power supply
C. White wire from cooktop
cable
D. Green (or bare) ground wires
from cooktop cable
E. 3-wire cable from cooktop
F. Junction box
G. White wire from power supply
H. UL fisted wire connector
I. Black wires
J. UL fisted or CSA approved
conduit connector
with wire
bushing
1. Connect the 2 black wires together using the UL listed wire
connectors.
Electrical Connection Options
If Your Home Has:
And You Will Be
Go to Section:
Connecting To:
4-wire
A fused
4-Wire Cable from
disconnect
or
Power Supply
circuit breaker
box
(12.7 crn)
2. Connect the red wire from power supply to the white wire
from the cooktop cable using the UL listed wire connectors.
3. Connect the green (or bare) ground wire from the cooktop
cable to the green (or bare) ground wire (in the junction box)
using the UL listed wire connectors.
4. Put a UL listed wire connector
on the end of the white wire
from power supply.
NOTE: Do not connect the bare ground wire to the neutral
(white) wire in the junction box.
3-wire
A fused
3-Wire Cable from
disconnect
or
Power Supply
circuit breaker
box
5. Install junction box cover.

Advertisement

loading

This manual is also suitable for:

Wce52424ab0