In order to assure the best results in service, proper operation and maximum efficiency, the original installation and adjustment
should be made by your dealer, his authorized agent, or by your local utility company before you attempt to operate the surface
unit.
LOCATION
Place unit where it will be well lighted. For proper cooking results, it must be level. THESE ELECTRIC COUNTER MOUNTED
SURFACE
UNITS ARE APPROVED
FOR INSTALLATION
IN COMBUSTIBLE
CABINETRY.
SEE INSTALLATION
DIAGRAM FOR THE APPROPRIATE
UNIT ON THE FOLLOWING PAGES OF THIS INSTRUCTION
SHEET.
OUTSIDE
WIRING
Your local utility company will tell you whether the present
electric
service to your home is adequate.
It may be
necessary to increase the size of the wiring to the house and
service switch to take care of the electrical load demanded
by the surface unit and/or oven. The wattage (K.W. rating)
load for the range is specified on the name plate on the unit.
HOUSE WIRING
Most local building regulations and codes require that all
electrical wiring be done by licensed electricians. All wiring
should conform to Local and National Electrical Codes. This
unit requires a single phase three wire 120/240 or a 120/208
volt, 60 Hz, AC circuit. Wiring codes require that a separate
circuit be run from the main entrance panel to the unit and
that it be equipped with separate disconnect switch and
fuses, either in the main entrance panel or in a separate
switch and fuse box.
UNIT CONNECTIONS
This unit is supplied with a 240/208 volt wiring system
consisting of 2 insulated conductors and 1 bare grounding
wire for use on a 3 wire 120/240 or a 120/208 volts, 60 Hz AC
branch circuit. Connect only to a 3-wire, 120/240-volt power
supply;
the
neutral
conductor
is not required
for the
operation of the appliance. The potential at the power supply
electrical connections shall be 150-volts-to-ground
or less.
The flexible armored conduit supplied with the unit must be
connected to an approved electrical junction box by means
of an approved conduit to box connector.
THE BARE WIRE IN THE UNIT CONDUIT IS CONNECTED
TO THE FRAME OF THE UNIT. THE FRAME OF THE UNIT
IS GROUNDED TO NEUTRAL OF THE BRANCH CIRCUIT
ONLY WHEN THIS BARE WIRE IS CONNECTED TO THE
NEUTRAL (WHITE) WIRE OF THE BRANCH CIRCUIT. If
used on new branch-circuit installations (1996 NEC), mobile
homes, recreational vehicles, or in an area where local
codes prohibit grounding through the neutral conductor, the
bare wire at the end of the unit conduit must be used to
ground the unit in accordance with local code. The red and
black wires must be connected to two conductors (red and
black) of the branch circuit. The neutral (white) wire of the
branch circuit must be properly insulated. Connect all wires
to the branch circuit with approved connectors. Use copper
or aluminum wire. If aluminum wire is used, use connectors
recognized for joining aluminum to copper.
APPROVED
CONNECTOR_
APPRoOxVE _
NEUTRAL'-'
_RANGE
CONDUIT
_
APPROVED
INSULATED
CONNECTIONS
L2
9219-947
BRANCH
CIRCUIT
(POWER
SUPPLY)
RANGE GROUNDED
THROUGH NEUTRAL CONDUCTOR
APPROVED
CONNECTOR-_
INSULATED--
B_
L1--
NEUTRAL --/
(
-- RANGE CONDUIT
)_
-BARE
-APPROVED
B©X
"APPRQVEDtNSULATED
CONNECTIONS
i
I._L2
9219-948
BRANCH
CIRCUIT
L_
POWER
SUPPLY
I"_,--S
E PARATE
GROUND
WIRING METHOD
IF CODE
DOES
NOT PERMIT
GROUNDING
THROUGH NEUTRAL CONDUCTOR
& ALSO REQUIRED IN MOBILE
HOMES.
WARNING:
Be sure UNIT is DISCONNECTED
from
POWER SUPPLY before examining any of the electrical
equipment.
8101 P480-60
(05-02-00)

Advertisement

loading

Summary of Contents for Maytag MEC4430AAB - 30 Inch Electric Cooktop

  • Page 1 READ "SAFETY INSTRUCTIONS" IN USE & CARE BOOK BEFORE USING UNIT In order to assure the best results in service, proper operation and maximum efficiency, the original installation and adjustment should be made by your dealer, his authorized agent, or by your local utility company before you attempt to operate the surface unit.
  • Page 2 Units shownin figures1 and 2 may be installedin combustible c ountertop a ndmustbespaced at least(1" from)combustible s idesandrearwallabove countertop. Unitshownin figure3 may be installed in combustible countertop a ndadjacent t o (0"from)combustible s ides andrearwallabove countertop. Dimension A =30-inches m inimum clearance b etween top ofthe cooking surface andthe bottom of anunprotected woodor metal c abinet, o r A = 24-inches minimum when bottom ofwoodor metalcabinet i s protected by notless...
  • Page 3: Ceramic Cooktop

    36" Cooktop with Coil Elements FRONT r2" FLEXIBLE CABLE LONG,FURNISHED AND INSTALLED BY MANUFACTURER (CONNECT TO 240/120 VOLTS ELECTRICAL MIN. SERVICE.) 6" WIRE LEAE 5/8- 7/8" M IN. 3/8" MIN. PLUS CLEARANCE INSIDE RIGHT ANGLE CONDUIT WIRE. FIGURE2 30" Smoothtop Ceramic Cooktop WIRE 6"...
  • Page 4 INSTR mostrador Unidades LEA LAS "INSTRUCCIONES DE SEGURIDAD'" EN EL MANUAL DE CUIDADO Y USO ANTES DE USAR LA UNIDAD Para garantizar los mejores resultados en el servicio, el funcionamiento apropiado y la maxima eficiencia, la instalaci6n y el ajuste originales debe realizarlos el distribuidor,...
  • Page 5 Las unidades mostradas e n las figuras1 y 2 pueden instalarse en mostradores combustibles y debenestar espaciadas cuando menos a (1"de)los ladosy la parte posterior combustible encima d elmostrador. La unidadmostrada en la figura3 puedeinstalarse e n mostradores combustibles yadyacentes a(0"de)loslados y lapared posterior encima d elmostrador.
  • Page 6 Superficie para cocinar con elementos de espiral de 36" 3 318" DE PROFUNDIDAD FRENTE DE LA UNIDAD CABLE FLEXIBLE DE 1/2" DE 36" DE LARGO, PROVlSTO E INSTALADO POR EL FABRICANTE (CONECTE A UN SERVlClO ELECTRICO DE MIN. 240/120 VOLTIOS.) CONDUCTOR DEL ALAMBREDE 6"...
  • Page 7 IMPORTANT - CONSERVER .4 L'USAGE DE L'INSPECTEUR EN ELECTRICITE LOCAL MISE EN Plaques de cuisson electriques montes sur un comptoir LIRE "MESURES DE SE'CURITE"" DANS LE MANUEL DE L'UTILISATEUR A VANT D'UTILISER L'APPAREIL Pour assurer un fonctionnement correct et efficient et des resultats optimums au niveau du service apres-vente, la pose et le reglage initiaux doivent etre realises par le revendeur,...
  • Page 8 Lesplaques d ecuisson d es figures 1 et2peuvent etre posees dansuncomptoir en materiau c ombustible et doivent etre placees a aumoins 1 podeparois enmateriau c ombustible au-dessus delasurface d ecuisson, aI'arriere e tsur lescetes. Laplaque d ecuisson d elafigures 3 peut ¢ tre posee dans un comptoir e n materiau combustible oQelle est adjacente (degagement de0 po)adesparois enmateriau c ombustible...