Diagnostic Error Code
000-000-XXX BIOS Test Passed
000-002-XXX BIOS Timeout
000-024-XXX BIOS Addressing test failure
000-025-XXX BIOS Checksum Value error
000-026-XXX FLASH data error
000-027-XXX BIOS Configuration/Setup error
000-034-XXX BIOS Buffer Allocation failure
000-035-XXX BIOS Reset Condition detected
000-036-XXX BIOS Register error
000-038-XXX BIOS Extension failure
000-039-XXX BIOS DMI data error
000-195-XXX BIOS Test aborted by user
000-196-XXX BIOS test halt, error threshold exceeded
000-197-XXX BIOS test warning
44
ThinkCentre Hardware Maintenance Manual
FRU/Action
No action
1. Flash the system. See "Updating (flashing) BIOS from
a disc" on page 324.
2. System board
1. Flash the system. See "Updating (flashing) BIOS from
a disc" on page 324.
2. System board
1. Flash the system. See "Updating (flashing) BIOS from
a disc" on page 324.
2. System board
1. Flash the system. See "Updating (flashing) BIOS from
a disc" on page 324.
2. System board
1. Run the Setup Utility program.
2. Flash the system. See "Updating (flashing) BIOS from
a disc" on page 324.
3. System board
1. Reboot the system.
2. Flash the system. See "Updating (flashing) BIOS from
a disc" on page 324.
3. Run memory test
4. System board
1. Flash the system. See "Updating (flashing) BIOS from
a disc" on page 324.
2. System board
1. Flash the system. See "Updating (flashing) BIOS from
a disc" on page 324.
2. System board
1. Flash the system. See "Updating (flashing) BIOS from
a disc" on page 324.
2. Adapter card
3. System board
1. Flash the system. See "Updating (flashing) BIOS from
a disc" on page 324.
2. System board
Information only Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using the
Setup Utility" on page 39.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.