HearthStone Quality Home Heating Products, Inc.
INSTALLING THE
H
R
EARTH
EQUIREMENT
When installing the Modena on carpet, vinyl, or any other
combustible floor other than wood flooring, it must be
installed on a metal or wood panel extending the full width
and depth of the stove.
C
T
C
LEARANCE
O
OMBUSTIBLES
Due to high surface temperatures, install the unit out of
traffic and away from furniture and draperies. Do not place
clothing and other flammable material on or near the heater.
When positioning the unit always maintain adequate
clearances around air openings into the combustion
chamber and allow for adequate ventilation. You must
maintain minimum clearances to combustibles as shown in
the illustrations of this section.
Ensure you consider the need for access to the gas control
valve access door on the front of the unit as well as full
access for periodic cleaning and servicing.
Caution:
These clearances represent minimum
distances in all cases, which, through testing in an
M
ODENA
/F
P
LOOR
ROTECTION
A = 16"
B = 1"
C = 11.5"
Figure 2 - Clearance to Combustibles
independent
laboratory
standards, will
combustion. We do not control the combustible
materials exposed to heat by this product;
therefore, an assessment must be made by the
installer to prevent consequential damage of walls
and flooring.
O
PENING THE FRONT DOOR
In order to gain access to the firebox you must open the
front door and remove the glass fame assembly. The front
door is held closed by a magnet. Simply pull the door open
to gain access to the glass frame. Remove the 12 screws
that mount the frame assembly to the stove using the 5/32"
Allen wrench provided. (See Figure 14). It is not necessary
to remove the four screws on hinge side of the glass frame.
Simply loosen the screws enough to allow the frame to slide
in and out. Replace these screws when the door is closed
for operation; the door will not seal without them.
.