KitchenAid KECD865HBT0 Installation Instructions Manual page 4

30" and 36" electric built-in ceramic downdraft cooktop
Table of Contents

Advertisement

Ventin9 system reqeirements
Venting system must terminate to the
outside.
Do Not terminate the vent system in an
attic or other enclosed space.
Do Not use 4-inch (10 cm) laundry-type
wall caps.
Use metal vent only. Exception: See
"optional venting under a concrete
slab", in "Venting methods" below.
Rigid metal vent is recommended. Do
not use plastic or metal foil vent.
To reduce risk of fire and to properly
exhaust air, be sure to vent air outside.
Do Not vent exhaust air into spaces
within walls or ceilings or into attics,
crawl spaces or garages.
Before
making
cutouts,
make sure there
is proper
clearance
within
the wall or
floor for the exhaust
vent.
Do Not cut a joist or stud unless
absolutely
necessary.
If a joist or stud
must be cut, then a supporting
frame
must be constructed.
Vent materials needed for installation
are not supplied.
Determine which venting method to use.
See "Venting methods," below.
Next, determine the equivalent vent length
using chart on Page 5. The maximum
equivalent vent length is 60 feet (18.3 m).
The blower
housing
is set to vent
straight out the back from the cooktop. To
vent down, left or right, see "Installation,"
Step 2, Page 6.
This downdraft
cooktop
is rated at
60 feet (18.3 m) of straight
vent or the
equivalent.
• if vent length
is 10 feet (3 m) or less,
6" (15.2 cm) diameter
round vent may
be used.
o tf vent length is more than 10 feet
(3 m), use 6" (15.2 cm) diameter round
or 3-1/4" x 10" (8.3 x 25.4 cm)
rectangular vent.
Thermal breaks: in areas of extreme
cold weather, it may be necessary to
provide a short length of nonmetallic duct
as close to the wall as possible to prevent
thermal conduction along the metal vent.
For attitudes above 4,800 ft (1372 m),
reduce recommended vent run by 20%.
For the most efficient and
quietest operation:
[]
Use 26=gauge minimum galvanized or
25=gauge minimum aluminum metal
vent. Poor=quality pipe fittings can
reduce air flow. (Note: Local codes may
require a heavier=gauge material.)
Flexible metal vent is Not
recommended.
[]
Do Not exhaust more than one
downdraft cooktop into a single vent
system=
[] The length of vent and number of
elbows should be kept to a minimum to
provide efficient performance.
[] The size of the vent should be uniform=
[]
Use the fewest number of 90 ° elbows=
[]
Do Not install two elbows together=
[]
Make sure there is a minimum of 18"
(45.7 cm) of straight vent between the
elbows if more than one elbow is used=
(Elbows too close together cause
excess turbulence that reduces airflow.)
[] Do Not use a 5" (12.7 cm) elbow in a
6" (15.2 cm) or 3=1/4" x 10"
(8.3 x 25.4 cm) system.
[] Do Not reduce back to 5" (12.7 cm)
system after using 6" (15.2 cm) or
3=1/4" x 10" (8.3 x 25.4 cm) fittings.
[] Avoid forming handmade crimps.
Handmade crimps may restrict airflow.
[]
Use the recommended vent caps for
proper performance. If an alternate wall
or roof cap is used, be certain cap size
is not reduced and that it has a
backdraft damper.
[]
Use duct tape to seal all joints in the
vent system.
[]
Use caulking to seal exterior wall or roof
opening around the cap.
Venting
methods
The cooktop may be vented through the wall or floor=Common venting methods and the
types of materials needed are shown=
Make sure there is proper clearance within the wall or floor for exhaust vent before
making cutouts=
\
11
eatsUdewall
_
peninsula
canner
or island
3ol/4" x 10"
(8,3 x 25.4 era
transition
elbow
inside wall to roof
directly
between
or overhang
outside
floor joists
peninsula
eition
_'
5_
elbow _
3=1/4" x 18"
(8.3 x 25,4 cm)
cabinet toe space
to outside