Setup Menu Firmware V 5.07 - Sound Devices 442 Nordic User Manual And Technical Information

Field mixers
Table of Contents

Advertisement

442/442N User Guide and Technical Information

Setup Menu Firmware v 5.07

The chart below shows the available setups for the 442 and 442N. The fl ashing left (top) meter LED
indicates the setup selected. The right meter LED indicates the available values, read from left to right.
L Meter
Position
Setup
442(442N)
Output Limiter
-30 (-30)
Threshold Adjustment
-20 (-24)
Input Limiter Defeat
Balanced TA3 Output
-14 (-22)
Level
-12 (-20)
Direct Output Level
-10 (-18)
Tone Oscillator Freq.
-8 (-16)
Tone Oscillator Level
-6 (-14)
Tone @ Direct Output
-4 (-12)
Slate Mic Toggle
-2 (-10)
Comm Mic Function
0 (-8)
PFL Level to Meter
2 (-6)
Monitor In Metering
4 (-4)
VU Reference Level
6 (-2)
Split-Ear Monitor A
8 (0)
Split-Ear Monitor B
Return Toggle
10 (2)
Assignment
Headphone
12 (4)
Attenuation with Tone
External Battery
14 (6)
Voltage Reference
16 (8)
Meter Ballistics Select
18 (10)
Default Restore
20
v. 5.07
Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.
Description
Sets the output limiter threshold in dBu
Keeps input limiters OFF when the LIM switch is activated
Selects the nominal output level of the active-balanced TA3
outputs
Selects the nominal output level of the active-balanced TA3
channel direct outputs
Selects the ƒ of the sine wave setup tone
Selects the output level of the tone oscillator in dBu
Selects whether tone is present on the Direct Outputs
Selects whether slate mic is activated when slate toggle switch
is activated
Allows return A|B toggle to be defeated and be reassigned to
send slate mic signal to right TA3 output when toggled
Selects whether PFL level is indicated on the output meter
Selects indication of monitor in signal level on the output meter
(post monitor gain control) when the monitor toggle is activated
Selects 0 VU to dBu reference
Changes monitoring to hear program audio in one ear and
monitor A in the other ear. Return A is summed and appears
in R (right) headphone and L program appears in L (left) head-
phone. Is only active when Return toggle switch is activated.
Changes monitoring to hear program audio in one ear and
monitor B in the other ear. Return B is summed and appears in
L (left) headphone and R program appears in R (right) head-
phone. Is only active when Return toggle switch is activated.
Allows the three-position monitor toggle to be assigned
depending on preferred monitor connection used
Reduces headphone level by 20 dB when the tone oscillator
is activated
Selects the Voltage range of the battery check function with
external power. Also adjusts the flashing power LED voltage
under external power.
Selects the meter ballistics options available at the meter
selection button.
Restores setup menu to the stored user default or to the
factory default settings
Setting (value on R Meter)
1 dB increments from +4 dBu to +20 dBu at Line Level
output
-30 (-30) = OFF, -20 (-24) = ON
-30 (-30) = Line-Level, -20 (-24) = Mic-Level
-30 (-30) = Line-Level, -20 (-24) = Mic-Level
-30 (-30) = 1000 Hz, -20 (-24) = 400 Hz,
-14 (-22) = 100 Hz
-30 (-30) = OFF, -20 (-24) = -20 dBu, -10 (-18) = -10
dBu,
1 dB increments to +8 dBu, 0 dBu = default.
-30 (-30) = ON, -20 (-24) = OFF
-30 (-30) = ON, -20 (-24) = ON with 1 second of 400 Hz
tone preceding, -14 (-22) = OFF
-30 (-30) = OFF, -20 (-24) = ON
-30 (-30) = ON, -20 (-24) = OFF
-30 (-30) = OFF, -20 (-24) = ON
-30 (-30) = 0 VU = 0 dBu, -20 (-24) = 0 VU = +4 dBu, -14
(-22) = 0 VU = +8 dBu , -12 (-20) = 0 VU/Peak = +1 dBu,
-10 (-18) = 0 VU/Peak = +2 dBu, -8 (-16) = 0 VU/Peak =
+3 dBu, -6 (-14) = 0 VU/Peak = +4 dBu, -4 (-12) = 0 VU/
Peak = +5 dBu, -2 (-10) = 0 VU/Peak = +6 dBu, 0 (-8) = 0
VU/Peak = +7 dBu, 2 (-6) = 0 VU/0 Peak = +8 dBu
-30 (-30) = OFF, -20 (-24) = ON
-30 (-30) = OFF, -20 (-24) = ON
-30 (-30) = A|OFF|B, -20(-24) = B|OFF|A,
-14 (-22) = A|OFF|A, -12 (-20) = B|OFF|B
-30 (-30) = ON, -20 (-24) = OFF
1 = -30 (-30), 2 = -20 (-24), 3 = -14 (-22),
4 = -12 (-20), 5 = -10 (-18), 6 = -8 (-16), 7 = -6 (-14)
see Powering for index.
-30 (-30) = VU|PPM|VU-PPMHold|VU-PPM,
-20 (-24) = PPM|VU-PPMHold|VU-PPM,
-14 (-22) = VU|VU-PPMHold|VU-PPM,
-12 (-20) = PPM|VU-PPM,
-10 (-18) = VU-PPM|VU-PPMHold
-30 (-30) = OFF, -20 (-24) = User Default,
-14 (-22) = Factory Default