ManufacturersNumber (Mfr No-See RatingPlate)
ALL Models
Specifications
NTC605OFB/
NTC6075FB/
NTC6075HF/
NTC6100GF/
NTC6100KF/
NTC6100KJ/
NTC6125KJ/
GNEO50B12
GNEO75B12
GNEO75F16
GNE100F14
GNEIOOF20
GNEIOOJ20
GNE125J20
NTN605OFB/
NTN6075FB/
NTN6075HF/
NTN6100KF/
NTN6100KJ/
NTN6125KJ/
NNEO50B12
NNEO75B12
NNEO75F16
NNEIOOF20
NNEIOOJ20
NNE125J20
General
Input (Btuh)
50,000
75,000
75,000
100,000
100,000
100,000
125,000
Output(Btuh)
40,000
59,000
59,000
79,000
79,000
79,000
99,000
Temp. Rise (F)
35-65
35-65
25-55
45-75
35-65
35-65
40-70
Electrical(Votts/Hz!FLA)
115/60/5.3
115/60/5.3
115/60/12.0
115/60/7.5
115/60/12.0
115/60/12.0
115/60/12.0
Gas
Type
Nat
I LP Nat I,P
Nat
Nat
Nat I,P
Nat I,P
Nat
I 'P
Transformer Size (VA)
40
40
40
40
40
40
40
T'stat Heat Anticipator
.30
.30
.30
.30
.30
.30
.30
Gas & Ignition
GasType
Nat
LP
Nat
LP
Nat
LP
Nat
LP
Nat
LP
Nat
LP
Nat
LP
Std.Main Orifices (No/Size)
2/#42
2/#54
3/#42
3/#54
3/#42
3/#54
4/#42
4/#54
4/#42
4/#54
4/#42
4/#54
5/#42
5/#54
GasValve HoneywellSV
9501
9501
9501
9501
9501
9501
9501
9501
9501
9501
9501
9501
9501
9501
RegulationType
SNAP
SNAP
SNAP
SNAP
SNAP
SNAP
SNAP
SNAP
SNAP
SNAP
SNAP
SNAP
SNAP
SNAP
ManifoldPress.(Inch'sWC)
3.5
10.0
3.5
10.0
3.5
10.0
3.5
10.0
3.5
10.0
3.5
10.0
3.5
10.0
PilotOrifice Size
.018
.011
.018
.011
.018
.011
.018
.011
.018
.011
.018
.011
.018
.011
IgnitionType/SeriesHoneywell
HSP
HSP
HSP
HSP
HSP
HSP
HSP
Lock-Out Time
NA
NA
NA
NA
NA
NA
NA
Combustion
FlueOutlet Size (Inches)
3
3
3
3
3
3
3
Std.OutletTemp (F)
<480
<480
<480
<480
<480
<480
<480
Limits& Controls
Thermal Sensor (F)
300
300
300
300
300
300
300
LimitControlSetting (F)
See PartsList
See PartsList
See PartsList
See PartsList
SeeParts List
SeeParts List
See PartsList
Auxiliary Umit ('F)
130
130
130
130
130
130
130
Std.PressureSw. (Part No)
1010897
1010897
1010897
1010896
1010896
1010896
1010898
Press (Close)
-0.50
-0.50
-0.50
-0.60
-0.60
-0.60
-0.75
Press (Open)
-0.40
-0.40
-0.40
-0.50
-0.50
-0.50
-0.65
Fan Control(Type)
HW ST9120
HW ST9120
HW ST9120
HW ST9120
Fan Control
On
30/60
30/60
30/60
30/60
(Timed-secs)
Off
60,100,140,180
60,100,140,180
60,100,140,180
60,100,140,180
Blower Data
Type & Size
10-8
10-8
10-10
10-10
11-10
11-10
11-10
MotorAmps/Rpm
6.5/1050
6.5/1050
10.3/11O0
8.0/1050
10.6/11 O0
11.9/900
11.9/900
MotorType/H.p.
PSC/1/3
PSC/1/3
PSC/1/2
PSC/1/2
PS0/3/4
PS0/3/4
PS0/3/4
Cap. Mfd/Volts
5/370
5/370
10/370
7.5/370
10/370
10/370
10/370
FilterType
Washable
Washable
Washable
Washable
Washable
Washable
Washable
FilterSize (")
14x25xl
14x25xl
16x25x1
16x25x1
16x25xl
16x25xl
16x25x1(2)
Min. CoolCap. (Tons)
1.5
1.5
3
1.5
3
3
3
Max. CoolCap. (Tons)
3
3
4
3.5
4.5
5
5
Gas Conversion
Kits
Natto LPNAHFO02LP "1009509 or NAHL002LP"1160991
LPto Nat
'1009510
LP HighAltitude
"1160992
Nat HighAltitude
"1160993
*Must be ordered from ServiceParts