Drum Dehumidifier - Minolta EP3050 Operator's Manual

Table of Contents

Advertisement

120

5. Drum Dehumidifier

During high humidity periods or when there are sudden rapid changes in humidity (especially
when you are using a heater in winter), condensation
*2
Drum
, resulting in blotchy copies. In such instances, use the Drum Dehumidifier function to
dry the surface of the PC Drum.
Copy Made Before Drum Dehumidifier
Using the Drum Dehumidifier
Press the User Mode Key.
1
User Mode
Touch
Drum Defumidifier
2
User Mode
Select a function by pressing the
key.
Job Memory
Zoom Mem-
Input
ory Input
Toner Re-
Drum De-
Plenisher
humidifier
This sets the copier into the Drum
Dehumidifier cycle which lasts for
about 3 minutes.
*1
Drum De-
humidifier
3
1134P356CA
.
Exit
Meter
Count
User's
Choice
1075O139CA
1075O139CA
could form on the surface of the PC
Copy Made After Drum Dehumidifier
Make a copy to check that the copy
image is clear.
Run the Drum Dehumidifier cycle
once again if the copy image is not yet
clear.
Useful Tip
A copy cycle can be initiated even while
the copier is in the Drum Dehumidifier
cycle.
NOTE
The copier cannot be set into the Drum
Dehumidifier cycle while it is warming
up.
*1
Condensation:
A phenomenon in which small
drops of water are formed on cold
surfaces, such as the surface of the
PC Drum.
*2
PC Drum:
Functions in the copier as film in a
camera.
1134P374CA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ep4050

Table of Contents