Download Print this page

KitchenAid KGRS505XSS01 Installation Instructions Manual page 8

30" (76.2 cm) double oven gas ranges

Advertisement

Available languages

Available languages

Mc {®
s ConnecS!
4.
Explosion Hazard
Use a new CSA International
approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Gas supply pipe must be located within the shaded area as
shown in the "Cabinet Dimensions"
illustration in "Location
Requirements"
section.
A
/
C
A. Gas pressure regulator
B. Adapter
C. Flexible connector
D. Manual shutoff valve
Complete
connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
Typical flexible connection
1. Apply pipe-joint compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a 15/le"combination
wrench and an adjustable wrench to
attach the flexible connector to the adapters. Check that
connector
is not kinked.
.......C
A. Gas pressure regulator
B. Use pipe-joint
compound.
C. Adapter (must have 7/2"male
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F 7/2"or 3/4"gas pipe
G. Use pipe-joint
compound.
H. Adapter
2=
3=
A. Closed valve
B. Open valve
Test all connections
by brushing on an approved
noncorrosive
leak-detection
solution. If bubbles appear, a
leak is indicated. Correct any leak found.
Remove cooktop burner caps and grates from parts
package. Align recess in burner caps with pins in burner
base. Burner caps should be level when properly positioned.
If burner caps are not properly positioned, surface burners
will not light. Place burner grates over burners and caps.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
4. Plug into a grounded 3 prong outlet.
8

Advertisement

loading