Carefully slide range into cabinet
opening.
Carefully slide range into cabinet opening while inserting
rear leveling leg into and FULLY ENGAGING THE ANTI-TIP
BRACKET (See Fig. 26). Make sure that the flexible
appliance conduit (Fig. 18) and the power cord (Fig. 20)
folds into the remaining open floor area behind the range
warmer or storage drawer. Make sure that the flexible
appliance
conduit does not become pinched or kinked!
Pre-shape the flexible appliance conduit and power cord if
necessary to insure that the range slides into cabinet
opening properly. Be sure to check level of the range by
placing a level horizontally on an oven rack (See Fig. 27).
Surface
burner heads, cap & grates.
It is very important to make sure that all of the surface
burner heads, surface burner caps and surface burner
grates are installed correctly.
Your appliance was shipped with the burner heads and
burner caps assembled in the correct locations (Fig. 38).
Should you need to re-install the burner caps please refer
to the Use & Care guide for more information.
REMEMBER
--
DO NOT ALLOW
SPILLS,
FOOD,
CLEANING
AGENTS OR ANY OTHER MATERIAL TO
ENTERTHE
GAS ORIFICE HOLDER OPENING. Always keep the Burner
Caps and Burner Heads in place whenever the surface
burners are in use.
Check electric
ignition
of surface
burners.
Operation of electric igniters should be checked after range
and supply line connectors have been carefully checked for
leaks and range has been connected to electric power.
1.
Place cooking utensil on surface burner.
2.
Push the knob in and turn counterclockwise
out of the OFF
position (See Fig. 1).
3.
Release the knob and rotate to the LITE position. Note: All
electronic
surface
ignitors
will spark
at the same time.
However, only the burner you are turning on will ignite.
4.
Visually check that the burner has lit.
5.
Push the control knob in and turn counterclockwise
to the
desired flame size. The control knobs do not have to be set
at a particular setting. Use the guides and adjust the flame
as needed. DO NOT cook with the surface control knob in the
LITE position (The electronic ignitor will continue to spark if
the knob is left in the LITE position).
11
1.
5,000 BTU Simmer Burner.
2.
10,000 BTU Bridge Burner.
3.
9,500BTU Power Burner.
4.
12,000or
14,200BTU Power Burner.
5.
18,000 BTU Double Burner (some models).
Fig. 38
Fig. 39
Adjust
the "LO" setting
of surface
burner
valve (for linear flow valves
only).
If burner goes out, reset control to OFF.
Remove the burner control knob.
Use a thin-bladed
screwdriver and adjust the inner burner
flame size with the right-hand set screw (See Fig. 40).
Adjust the outer burner flame size with the lower set screw
(See Fig. 40). Turn counterclockwise
to increase flame size.
Turn clockwise to decrease flame size.
Test to verify if "LO or LOW" setting should be adjusted
(right front position ONLY)
1.
Push in and turn knob to (lite) until burner ignites.
2.
Push in and quickly turn knob to LOWEST POSITION.
3.
If burner goes out, reset control to OFR
4.
Remove the burner control knob.
5.
Use a thin-bladed
screwdriver and adjust the inner
burner flame size with the right-hand set screw (See Fig.
40). Adjust the outer burner flame size with the lower
set screw (See Fig. 40). Turn counterclockwise
to
increase flame size. Turn clockwise to decrease
flame size.

Hide quick links: