PROGRAMMING THE CM707
f.. i).Press.the.COPY DAY.button.to.copy.Monday's.program.into.Tuesday..The.display.will.go.blank.
apart.from.the.'non.flashing'.day.indicator,.which.indicates.the.day.copied.and.the.'flashing'.target.
day.to.copy.the.program.to..To.accept.this.day.press.the.green.
target. day. press. the. DATE/DAY. button. until. the. 'flashing'. day. indicator. is. under. the. required.
day,.then.accept.it.by.pressing.the.green.
becomes the day that is copied if the COPY DAY button is pressed again.
.
OR
.
ii).Press.the.DATE/DAY button.to.move.the.day.indicator.to.Tuesday.(Day.2)..The.program.for.that.
day.can.then.be.adjusted.by.following.steps.b to e..Programs.for.the.remaining.days.can.be.set.in.
the.same.way,.using.the.DATE/DAY button.to.move.to.the.next.day.
To.exit.the.programming.mode.select.the.desired.operating.mode.by.pressing.the.AUTO,.MAN or.
OFF buttons..Note: To run the adjusted program select the AUTO mode.
Disabling / Enabling Time Periods
The.thermostat.has.4.periods.each.day.that.can.be.programmed,.but.you.may.not.need.all.of.these.
switch.points.for.your.heating.requirements..Therefore,.any.period.from.2.to.4.can.be.removed.from.
(or.returned.to).the.heating.program.profile.
To disable or enable time periods:
a.. To.disable.unwanted.periods.go.to.the.desired.period.(  .to. 4 )..using.the.PROGRAM.
buttons.to.navigate,.ensure.the.correct.period.is.highlighted.with.the.flashing.square.symbol..
Press.and.hold.the. .button.for.at.least.2.seconds.and.the.display.will.indicate.the.period.has.
been.removed.from.the.program.
b.. To.enable.periods.again.follow.the.same.procedure.as.above,.navigating.to.the.already.disabled.
period..To.enable.this.period.again.press.and.hold.the. .button.for.at.least.2.seconds.
OPERATING THE CM707
Choosing the Operating Mode
The.thermostat.can.operate.in.three.different.modes:.Automatic,.Manual.or.Off..To.set.the.operating.
mode. press. either. of. the. AUTO,. MAN or. OFF buttons.. The. screen. indicates. which. mode. is.
currently.active.by.displaying.AUTO,.MAN or.OFF.
•. AUTO (automatic).mode.sets.the.thermostat.to.follow.the.built-in.temperature.program.(default.
or.personalised)..Operating.the.thermostat.in.this.mode.is.the.best.way.to.maintain.a.high.level.
of.temperature.comfort.whilst.maximising.your.energy.savings.
•. MAN (manual).mode.sets.the.thermostat.to.act.as.a.simple.thermostat.with.a.fixed.setpoint.
throughout. the. day.. The. setpoint. can. be. adjusted. from. 5°C. to. 35°C. by. using. the. .
buttons..The.thermostat.will.continue.to.maintain.this.temperature.until.another.operating.mode.
or.temperature.is.selected.
•. OFF.mode.sets.the.thermostat.to.control.to.a.minimum.temperature.setting.of.5°C.(default).that.
acts.as.a.frost.protection.measure.for.your.home.
.button..To.select.a.different.
.button..Note: Once the target day is confirmed it
'Efficient Daily Use'
.or.
'Using the Features'
. or.

.
.