Download Print this page

Payne PYIP180040 Installation, Start-Up And Service Instructions Manual page 2

Py1p single packaged gas heating/ electrical cooling units

Advertisement

/-COND
COIL
- 4 13/16"
()22.2)
43
11116"
4ll0B.B)
B/16
°
(312.?)
\
BLOWER
ACCESS
BURNER
AND
CONTROL
30X
PANEL
RIGHT
SIDE
VIEW
ACCESS
PANEL
REQ'D CLEARANCES
FOR SERVICING
in (mm)
Duct panel .............................
0
Unit top ...........................
36 (914)
Side opposite
ducts
.....................
36 (914)
Compressor
access
.....................
36 (914)
(Except for NEC requirements)
REQ'D CLEARANCES
TO COMBUSTIBLE
MAT'L
in. (mm)
Maximum extension
of overhangs
...............
48 (1219)
Unit top ...........................
14 (356)
Duct side of unit
........................
2 (51)
Side opposite
ducts
.....................
14 (356)
Bottom of unit
...........................
0
Flue panel
.........................
36 (914)
NEC REQ'D CLEARANCES
in. (mm)
Between units, control box side ................
42 (1067)
Unit and ungrounded
surfaces,
control box side
.........
36 (914)
Unit and block or concrete walls and other grounded
surfaces,
control box side
..................
42 (1067)
49 9116"
(1259.3)
COIL
RETURN
AIR
OPENING
(281,4)
I
l? l/1B'_
(433,9)
LOPT_ONAL SUPPLY
AIR OPENING
14
?liB"
(365.9)
(52,63
10 9116"
(263.R)
7/3" (22.2) BIA,
CONTROL
ENTRY_
\
t
(203.2)
I
1/8"
(2B.6)
DIA,
POWER
ENTRY
_
(90.51
i
i
!
_-I
5/E
_ 441,3)
OIA.
GASENTRY
1/2 _ - 14 NPT
GASCONNECTION
REAR
VIEW
i w
(58. O)
!
I
(29.6)
FLUE
PANEL
FLUE
HOOD
0 ?/3"
422.23)
ALTERNATE
LV ENTRY
EVAP
COIL
ACCESS
LEFT
SIDE
VIEW
I
W4"
(31.75)
_,ALTERNATE
POWER ENTRY
I
?/16
-2
3/18"
(39.3)
455.6)
COMPRE330R
ACCES5
PANEL
3/4"
NPT
(13,0)
DRAIN
OUTLET
FRONT
VIEW
UNIT
PYIP180040
PY1P024040
PYIP024060
PY1P030040
PYIP030060/080
PYIP036060/080
PYIP036100/120
PYIP042060/080
PYIP042100/120
ELECTRICAL
CHARACTERISTICS
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60,
208/230-3-60
208/230-1-60,
208/230-3-60
208/230-1-60,
208/230-3-60,
460-3-60
208/230-1-60,
208/230-3-60,
460-3-60
208/230-1-60,
208/230-3-60,
460-3-60
208/230-1-60,
208/230-3-60,
460-3-60
UNIT WEIGHT
Ib
kg
272
123
303
138
315
143
320
145
332
149
336
153
348
158
375
170
387
176
CORNER WEIGHT
UNIT HEIGHT
(Ib/kg)
(in./mm)
A
B
C
D
E
81/37
82/28
78/35
53/24
24 1/813
97/44
43/20
123/56
40/18
241/813
100/45
46/21
128/57
43/20
241/813
100/45
47/21
128/57
47/21
241/813
103/46
50/22
129/58
50/23
24 1/813
86/39
76/35
111/50
63/29
24 1/813
89/40
79/36
114/52
66/30
24 1/613
95/43
86/39
119/54
75/34
28 1/714
98/45
89/40
122/55
78/35
28 1/714
UNIT
PYIP018040
PY1P024040
PY1P024060
PY1P030040
PY1P030060/080
PY1P036060/080
PY1P036100/120
PYIP042060/080
PY1P042100/120
F
in./mm
169½d420 7
209½d522
3
in./mm
18/5½6/481 0
22/5½6/5826
CENTER
OF GRAVITY
in./mm
X
Y
Z
2507/637
20.59/523
2707/688
23.35/593
2698/685
23.27/591
2671/678
23.46/598
10.85/278
2715/689
22.38/568
2750/698
22.48/571
2740/696
22.44/570
2701/686
22.44/570
127/321
2694/684
22.44/570
LEGEND
CG
--
Center of Gravity
MAT'L
--
Materiat
COND
--
Condenser
NEC
--
National Electrical
Code
LV
--
Low Voltage
REQ'D
--
Required
NOTES:
1. Clearances must be maintained to prevent recirculation of air from outdoor-
fan discharge.
2 Adequate clearance around air openings into combustion
chamber must
be provided.
Fig. 2 -- PYIP018-042
Without
Base Rail, Unit Dimensions
--2--

Advertisement

loading