How To Shut Off Gas - Direct Ignition; Operating Instructions - Oil Gun; Operating Instructions - Gas Gun; How To Shut Off Gas- Gas Gun - Nordyne M1B Installation Instructions Manual

Downflow, direct vent (sealed combustion) forced air gas & oil furnaces
Table of Contents

Advertisement

How to Shut Off Gas - Direct Ignition
1. Set the thermostat
to the lowest setting.
2.Turn
off all electric
power to the appliance
before servicing
unit.
3. Set the furnace On-Off Switch to OFF.
o Honeywell (Figure 32):Turn gas control knob
clockwise to OFF, Robertshaw (Figure 33):
Push the gas control lever to OFF.
For oil, shut off all valves.
4. Replace the furnace door.
Operating
instructions
for Oil Gun Furnaces
If your furnace model number begins with M5S*,
the furnace is equipped with an ignition device
which automatically
lights the burner. Do not try
to light this furnace
manually.
1. Open all valves in the oil line.
2. Verify the fire door is closed.
3. Set the furnace On-Off switch to ON.
4. Set the thermostat
to the desired setting.
NOTE: M5 oil gun furnaces may be converted to
gas gun in the field by using the proper conversion
kit listed in the RPL.
Operating
instructions
for Gas Gun Models
If your furnace model number begins with M1 B,
the furnace does not have a pilot. Ignition is
accomplished
by a silicon carbide
hot surface
ignitor. A control module takes care of all lighting
and timing functions.
There
are no external
relays or timing devices. Do not try to light this
furnace
by hand. The control module
is not
field serviceable.
1. Before operation, smell for gas all around the
furnace,
especially
near the floor because
some gases are heavier than air and will settle
on the floor. If you detect gas, STOP and follow
all the safety instructions.
2. Set the thermostat
to the lowest setting.
3. Turn off all electric power to the appliance.
4. Turn off the gas valve:
Honeywell:
push in the gas control knob
and turn clockwise to OFF (Figure 32).
Robertshaw:
push the gas control lever to
OFF (Figure 33).The lever cannot be placed
in the off position unless it is pushed in
slightly. DO NOT FORCE!
5.Wait
ten minutes
to clear out any gas. If
you smell gas, STOP! and follow the safety
information. If gas is not detected, proceed to
the next step.
6. Set the furnace
On-Off
switch to the ON
position.
, Honeywell: turn knob on gas control counter
clockwise to ON.
, Robertshaw:
push the gas control lever to
ON.
22
7. Turn electric power to the appliance
ON.
8. Set the thermostat to H EAT and/or the desired
temperature
setting. The furnace should light
in approximately
45 seconds. If the appliance
will not operate, follow the instructions "How to
Shut Off Gas - Direct Ignition Furnace" (page
21) and call your service
technician
or gas
supplier.
In the event of any flashback
or explosion,
immediately
shut off the furnace and call your
service technician.
How to Shut Off Gas- Oil & Gas Gun
1. Set the thermostat
to the lowest setting.
2. Turn off all electric power to the appliance
at
the breaker or fuse box.
3. Set the thermostat
MODE switch to OFF.
4. Turn the gas valve OFF:
o Honeywell: push in and turn the gas control
knob clockwise to the OFF position (Figure
32).
. Robertshaw
- push the gas control lever to
the OFF position (Figure 33).
5. Replace the furnace door.
NOTE: M1 B gas gun furnaces may be converted
to oil gun in the field by using
the proper
conversion
kit listed in the RPL
Burner Adjustments
Burner settings are made at the factory. However,
these
settings
may change
during
shipping,
handEing, and instaEEation. The following
items
should be checked and readjusted if necessary.
Gas Pressure
The
gas pressure
can
be checked
with
a
manometer
at the pressure tap located on the
side of the gas valve. The gas valve pressure
regulator
can be adjusted
by removing
the
regulator selector stack and turning the slotted
insert located directly under the selector stack.
The regulator selector stack must be secured
in place before each pressure reading is taken.
Natural gas manifold pressure should be 3.5"
W.C. and L.R gas manifold pressure should be
10" W.C. Replace the gas pressure tap plug on
the gas valve.
Pilot Flame (Standinq Pilot Only)
The pilot flame can be adjusted by turning the
pilot adjustment
screw, located on top of the
gas valve (See Figure 30, page 20). The pilot
flame height should be between 3/4" and 1 ."The
flame tip should be visible just above the pilot
bracket when viewed through the observation
door. The same pilot orifice is used with both
natural and LP gas.