STARTUP AND ADJUSTMENTS
PLEASE READ ALL SAFETY iNFORMATION
BEFORE LIGHTING THE FURNACE
FiRE OR EXPLOSION HAZARD
WHATTO DO IFYOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your
building.
• Leave the building immediately.
• immediatelycall your gas supplier
from a neighbors phone. Foliowthe
gas suppliers instructions.
• if you cannot
reach
your
gas
supplier, call the fire department.
WARNING:
Before
placing
the furnace
in
service,
it must
be checked
to
ensure it is equipped for the type
of gas being used.The burner flame
must be observed and adjusted
if necessary.
Failure to observe
this caution
may result
in unsafe
operation, explosion and/or fire, or
asphyxiation.
See the Gas Supply
and Combustion Air sections.
. The first lighting of the furnace
after any
home
setup
must
be performed
by a
qualified
service
technician.
. If this appliance has a pilot that must be lit by
hand, follow these instructions
exactly.
. BEFORE
LIGHTING:
Smell
all around
the
furnace for gas and next to the floor. Some
gas is heavier than air and may settle on the
floor.
. Use only your hand to push in the gas control
lever. Never use tools. If the lever will not push in
by hand, don't tryto repair it. Force or attempted
repair may result in a fire or explosion. Call a
qualified service technician.
. Do not use this furnace if any part has been
under
water.
Immediately
call
a service
technician to inspect the furnace and to replace
any part of the gas valve or control system
which has been under water.
20
Lighting Instructions-
Standing
Pilot Models.
1. Set the thermostat
to the lowest setting.
2. Turn off all electric power to the appliance.
3. Remove the furnace door.
4. Push in and move the gas control lever to the
OFF positon (Figure 30). DO NOT FORCE!
5. Wait 10 minutes to clear out any gas. If you smell
gas, STOP! and read the Safety Information.
If you don't smell gas, proceed to step 6.
6. Find pilot - follow metal pilot tube from gas
control valve. Open hinged fire observation
door. The pilot is found at the end of the pilot
tube just left of the pilot shield (Figure 31).
7. Lightly depress the gas control lever and move
it to the ON position. Release and move the
lever to the PILOT position.
8. Move the control
lever to SET and hold.
Immediately
light
the pilot with a match.
Continue to hold the control lever for about one
(1) minute after the pilot is lit. NOTE: The pilot
flame is adjustable by turning the adjustment
screw located on the gas valve with a small
screwdriver. See Figure 29.
9. Release the lever and it will spring back to the
PILOT position. NOTE: Pilot should remain lit.
If it goes out, repeat steps 4 through 8 above. If
the lever does not spring back when released,
immediately call your service technician or gas
supplier. If the pilot will not stay lit after several
tries, move the gas control lever to OFF and
call your service technician or gas supplier.
10. Move the gas control lever to ON.
11. Turn on all electric power to the furnace.
]
]
Position
Gas Control Lever
Pilot Position
Figure 30. Standing
Pilot Valve
P ILOT
BRACKET
Figure 31. Lighting
The Furnace