WORKLIGHT BULB REPLACEMENT
When the light bulb is worn out and will no longer work, unfasten the screws that hold the lamp
cover, and then gently remove the bulb from the holder by pushing 'in' and turning counterclockwise.
Contact distributor for replacement bulbs. To replace, gently push the light bulb into the socket and
turn clockwise, and then reattach the lamp cover by reversing the instructions provided above.
TROUBLESHOOTING
Service on this Bench Grinder should only be performed by an authorized, qualified technician.
SYMPTOM
Motor will not start.
Motor will not start – fuses
or circuit breakers tripping
or blowing.
Motor overheats.
Motor stalls (resulting in
blown
fuses
or
tripped
circuit).
coolant tray
PROBABLE CAUSE
1. Low Voltage.
2. Open circuit in motor or loose
connections.
3. Blown fuse or breaker.
1. Short circuit in line, cord or
plug.
2. Short circuit in motor or loose
connections.
3. Incorrect fuses or circuit
breakers in power line.
4. Motor overloaded.
5. Extension cord too long and of
insufficient gauge (weight).
1. Short circuit in motor or loose
connections.
2. Low voltage.
3. Incorrect fuses or circuit
breakers in power line.
4. Motor overload.
Page of 14
10
CORRECTIVE ACTION
1. Check power source for proper
voltage.
2. Inspect all lead connection on
motor for loose or open
connections. (Send for
Servicing.)
3. Short circuit. (Send for
Servicing.)
4. Improper match between tool
and circuit, fuse or breaker.
1. Inspect cord or plug for damaged
insulation and shorted wires.
2. Inspect all connections on motor
for loose or shorted terminals
and/or worn insulation.
3. Install correct fuses or circuit
breakers or switch tool to an
appropriately sized circuit.
4. Reduce load on motor.
5. Utilize an extension cord of
appropriate gauge and length or
plug tool directly into outlet.
1. Inspect connections on motor for
loose or shorted terminals or
worn insulation. (Send for
Servicing.)
2. Correct low voltage conditions
(for example: improper extension
cord length and/or gauge).
3. Install correct fuses or circuit
breakers or plug tool into an
appropriate circuit, matched to
an appropriate fuse or breaker.
4. Reduce the load on the motor.