Block
._d
Terminal
Wire
1-1/8"
Dia.
Direct
Connection
Hole. Punch
out knockout
for 1-3/8"
Dia.
Cord Kit Hole
A strainrelief
supplied
by the user
/-
must be installed
at
/To
240 V receptacle
this location
NOTE." Be sure to remove
the supplied
/_t
grounding
strap
Figure 4
Cablefrom
Residence
White
Wire
i
(Neutral)
Black
.._,"
_
Wires-
_
_
_Red
i
::!"::
!:
__"i
\'_Whit::_ire
Green _
U.L._ii_::_ral)
(or Bare Copper)
Conduit
Wire
Cablefrom
Connector
Range
(or CSAlisted)
Figure 5
3-Wire (Grounded
Neutral) Electrical
System
(Example: Junction
Box)
Direct
Electrical
Connection
to the
Circuit
Breaker,
Fuse Box or Junction
Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief
at each end of the
cable. At the appliance end, the cable goes through the
Direct Connection
Hole (see Figure 4) on the Cord
Mounting
Plate. Wire sizes (copper
wire only) and
connections must conform to the rating of the appliance.
Where local codes permit
connecting
the appliance-
grounding
conductor
to the neutral
(white)
wire
(see Figure 5):
(The 3-conductor
cord or cable must be replaced with a
4-conductor cord or cable where grounding through the
neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box
connect the appliance and residence cable wires as
shown in figure 5.
Where local codes DO NOT permit connecting
the
appliance-grounding
conductor
to the neutral
(white)
wire, or if connecting
to 4-wire
electrical
system (see Figure 6):
1.
Disconnect the power supply.
2.
Separate the green (or bare copper) and white
appliance cable wires.
3.
In the circuit breaker, fuse box or junction box:
connect appliance and residence cable wires as
shown in figure 6.
Cablefrom
Residence
Junction
Box
Green
(or Bare Copper)
Wire_
Red_.
_
[w%
Green
(or Bare Copper)
Wire
__._
White Wire
eutral)
Wires 1
_l /-_
Whi.__ (Nt:tWil;e
\_U.L.qisted
Cable from
Conduit
Appliance
Connector
(or CSA listed)
Figure 6 - 4-Wire Electrical
System
(Example: Junction
Box)