Summary of Contents for Supero SUPERSERVER 5038D-i

  • Page 1 UPER ® UPER ERVER 5038D-i USER’S MANUAL 1.0a...
  • Page 2 The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
  • Page 3: About This Manual

    About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 5038D-i. In- stallation and maintenance should be performed by experienced technicians only. The SuperServer 5038D-i is a high-end server based on the SC731i-300B mini- tower chassis and the Super X10SLL-F single processor serverboard.
  • Page 4 UPER ERVER 5038D-i User's Manual Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X10SLL-F serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
  • Page 5 Preface Notes...
  • Page 6: Table Of Contents

    UPER ERVER 5038D-i User's Manual Table of Contents Chapter 1 Introduction Overview ......................1-1 Motherboard Features ..................1-2 Processors ...................... 1-2 Memory ......................1-2 Serial ATA ......................1-2 I/O Ports ......................1-2 Chassis Features .................... 1-3 System Power ....................1-3 SATA Subsystem .....................
  • Page 7 Table of Contents Redundant Power Supplies ................4-12 Backplane Voltage ..................4-13 Comply with Local and National Electrical Codes ........4-14 Product Disposal ................... 4-15 Hot Swap Fan Warning ................. 4-16 Power Cable and AC Adapter ..............4-18 Chapter 5 Advanced Motherboard Setup Handling the Motherboard ................
  • Page 8 UPER ERVER 5038D-i User's Manual Fan Failure ...................... 6-6 Replacing the System Fan ................. 6-6 Drive Bay Installation ..................6-7 SATA Drives ....................6-7 Installing Drives in the Optional Drive Bays ........... 6-9 Chapter 7 BIOS Introduction ...................... 7-1 Starting BIOS Setup Utility ................7-1 How To Change the Confi...
  • Page 9: Chapter 1 Introduction

    Chapter 1 Introduction Overview The SuperServer 5038D-i is a high-end server comprised of two main subsystems: the SC731i-300B server chassis and the X10SLL-F single processor motherboard. Please refer to our web site for information on operating systems that have been certifi...
  • Page 10: Motherboard Features

    ERVER 5038D-i User's Manual Motherboard Features At the heart of the SuperServer 5038D-i lies the X10SLL-F, a single processor motherboard based on the Intel® C222 chipset. Below are the main features of the X10SLL-F (see Figure 1-1 for a block diagram of the chipset).
  • Page 11: Chassis Features

    Chapter 1: Introduction Chassis Features The SC731i-300B is a mini-tower chassis with a unique design that allows most confi gurations to be performed without the need for tools The following is a general outline of the main features of the SC731i-300B chassis. System Power The SC731i-300B features a high-effi...
  • Page 12: System Block Diagram

    UPER ERVER 5038D-i User's Manual Figure 1-1. Intel C222 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. #B-1 VR12.5 #B-0 3 PHASE #A-1 PCI-E X16 G3 #A-0 PCI-E x16 #0-15 Haswell-DT...
  • Page 13: Contacting Supermicro

    Chapter 1: Introduction Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands Tel:...
  • Page 14 UPER ERVER 5038D-i User's Manual Notes...
  • Page 15: Chapter 2 System Setup

    Unpacking the System You should inspect the box the SuperServer 5038D-i was shipped in and note if it was damaged in any way. If the server itself shows damage, you should fi le a damage claim with the carrier who delivered it.
  • Page 16 UPER ERVER 5038D-i User's Manual Figure 2-1. Accessing the Inside of the 5038D-i Release Tab Handle...
  • Page 17: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview There are four LEDs on the control panel to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components. The control panel also is where to fi...
  • Page 18: Nic

    UPER ERVER 5038D-i User's Manual Indicates network activity on the Gigabit LAN port when fl ashing. Overheat/Fan Fail When this LED fl ashes it indicates a fan failure. When on continuously (on and not fl ashing) it indicates an overheat condition, which may be caused by cables ob- structing the airfl...
  • Page 19: Chapter 4 Standardized Warning Statements For Ac Systems

    Chapter 4: Warning Statements for AC Systems Chapter 4 Standardized Warning Statements for AC Systems About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance.
  • Page 20 UPER ERVER 5038D-i User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
  • Page 21 Warning Statements for AC Systems ‫ﺟﺴﺪﻳﺔ‬ ‫ﺍﺻﺎﺑﺔ‬ ‫ﺗﺘﺴﺒﺐ ﻓﻲ‬ ‫ﺣﺎﻟﺔ ﻳﻤﻜﻦ ﺃﻥ‬ ‫ﺍﻧﻚ ﻓﻲ‬ ‫ﺧﻄﺮ‬ ‫ﻳﻌﻨﻲ‬ ‫ﻫﺬﺍ ﺍﻟﺮﻣﺰ‬ !‫ﺗﺤﺬﻳﺮ‬ ‫ﺍﻟﺪﻭﺍﺋﺮ‬ ‫ﺑﺎﻟﻤﺨﺎﻁﺮ ﺍﻟﻨﺎﺟﻤﺔ ﻋﻦ‬ ‫ﻦ ﻋﻠﻰ ﻋﻠﻢ‬ ، ‫ﻛ‬ ‫ﻣﻌﺪﺍﺕ‬ ‫ﺗﻌﻤﻞ ﻋﻠﻰ ﺃﻱ‬ ‫ﻗﺒﻞ ﺃﻥ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫ﺣﻮﺍﺩﺙ‬ ‫ﺃﻱ‬ ‫ﻭﻗﻮﻉ‬ ‫ﻤﻨﻊ‬ ‫ﻟ‬ ‫ﺍﻟﻮﻗﺎﺋﻴﺔ‬...
  • Page 22: Installation Instructions

    UPER ERVER 5038D-i User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
  • Page 23: Circuit Breaker

    Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. 警告 此产品的短路(过载电流)保护由建筑物的供电系统提供,确保短路保护设备的额定电 流不大于250V,20A。 警告 此產品的短路(過載電流)保護由建築物的供電系統提供,確保短路保護設備的額定電 流不大於250V,20A。...
  • Page 24: Power Disconnection Warning

    UPER ERVER 5038D-i User's Manual Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A. Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components.
  • Page 25 Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché...
  • Page 26: Equipment Installation

    UPER ERVER 5038D-i User's Manual Equipment Installation Warning! Only trained and qualifi ed personnel should be allowed to install, replace, or service this equipment. 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifi ziertem Personal gestattet werden.
  • Page 27: Restricted Area

    Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalifi ceerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
  • Page 28: Battery Handling

    UPER ERVER 5038D-i User's Manual ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ .('‫כלי אבטחה בלבד )מפתח, מנעול וכד‬ ‫ﻣﺤﻈﻮﺭﺓ‬ ‫ﻣﻨﺎﻁﻖ‬ ‫ﻟﺘﺮﻛﻴﺒﻬﺎ ﻓﻲ‬ ‫ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ‬ ‫ﺗﺨﺼﻴﺺ‬ ‫ﺗﻢ‬ ،‫ﺃﺩﺍﺓ ﺧﺎﺻﺔ‬ ‫ﻣﻦ ﺧﻼﻝ ﺍﺳﺘﺨﺪﺍﻡ‬...
  • Page 29 Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
  • Page 30: Redundant Power Supplies

    UPER ERVER 5038D-i User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
  • Page 31: Backplane Voltage

    Chapter 4: Warning Statements for AC Systems ‫ﺍﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ‬ ‫ﺑﻮﺣﺪﺍﺕ‬ ‫ﻋﺪﺓ ﺍﺗﺼﺎﻻﺕ‬ ‫ﺠﻬﺎﺯ‬ ‫ﺍﻟ‬ ‫ﻳﻜﻮﻥ ﻟﻬﺬﺍ‬ ‫ﻗﺪ‬ ‫ﺍﻟﻜﻬﺮﺑﺎء‬ ‫ﻋﻦ‬ ‫ﻮﺣﺪﺓ‬ ‫ﺍﻟ‬ ‫ﻟﻌﺰﻝ‬ ‫ﻛﺎﻓﺔ ﺍﻻﺗﺼﺎﻻﺕ‬ ‫ﻳﺠﺐ ﺇﺯﺍﻟﺔ‬ Waarschuwing Deze eenheid kan meer dan één stroomtoevoeraansluiting bevatten. Alle aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken. Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is...
  • Page 32: Comply With Local And National Electrical Codes

    UPER ERVER 5038D-i User's Manual ‫מתח בפנל האחורי‬ !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ .‫העבודה‬ ‫ﺍﻟﻠﻮﺣﺔ‬ ‫ﺃﻭﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ‬ ‫ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ‬ ‫ﻣﻦ‬ ‫ﺧﻄﺮ‬ ‫ﻫﻨﺎﻙ‬ ‫ﻫﺬﺍ ﺍﻟﺠﻬﺎﺯ‬ ‫ﺧﺪﻣﺔ‬ ‫ﻛﻦ ﺣﺬﺭﺍ ﻋﻨﺪ‬ ‫ﻳﻌﻤﻞ‬ ‫ﺍﻟﻨﻈﺎﻡ‬ ‫ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ‬...
  • Page 33: Product Disposal

    Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫התקנת‬ ‫ﺍﻟﻤﺘﻌﻠﻘﺔ‬ ‫ﺍﻟﻤﺤﻠﻴﺔ ﻭﺍﻟﻮﻁﻨﻴﺔ‬ ‫ﻘﻮﺍﻧﻴﻦ‬ ‫ﻳﺠﺐ ﺃﻥ ﻳﻤﺘﺜﻞ ﻟﻠ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬...
  • Page 34: Hot Swap Fan Warning

    UPER ERVER 5038D-i User's Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
  • Page 35 Chapter 4: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
  • Page 36: Power Cable And Ac Adapter

    UPER ERVER 5038D-i User's Manual Power Cable and AC Adapter Warning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fi re. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certifi...
  • Page 37 Chapter 4: Warning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie. Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifi...
  • Page 38 UPER ERVER 5038D-i User's Manual Notes 4-20...
  • Page 39: Chapter 5 Advanced Motherboard Setup

    Chapter 5: Advanced Motherboard Setup Chapter 5 Advanced Motherboard Setup This chapter covers the steps required to install processors and heatsinks to the X10SLL-F motherboard, connect the data and power cables and install add-on cards. All motherboard jumpers and connections are described and a layout and quick reference chart are included in this chapter.
  • Page 40: Processor And Heatsink Installation

    UPER ERVER 5038D-i User's Manual Processor and Heatsink Installation Notes: • Always connect the power cord last and always remove it before adding, re- moving or changing any hardware components. Make sure that you install the processor into the CPU socket before you install the CPU heatsink.
  • Page 41 Chapter 5: Advanced Motherboard Setup 5. Align the CPU key, which is a semi- circle cutout, against the socket CPU Key key, which is the notch below the gold color dot on the side of the socket. 6. Align pin 1 of the CPU against pin 1 of the CPU socket.
  • Page 42: Installing The Heatsink

    UPER ERVER 5038D-i User's Manual Installing the Heatsink 1. Locate the CPU Fan power connec- tor on the motherboard. 2. Position the heatsink so that the heatsink fan wires are closest to the CPU fan power connector and are not interfered with other compo- nents.
  • Page 43: Removing The Heatsink

    Chapter 5: Advanced Motherboard Setup 8. Repeat Step 7 to insert all four heatsink fasteners into the mounting holes. 9. Once all four fasteners are securely inserted into the mounting holes, and the heatsink is properly installed on the motherboard, connect the heatsink fan wires to the CPU Fan connector.
  • Page 44: Connecting Cables

    UPER ERVER 5038D-i User's Manual Connecting Cables Now that the processors are installed, the next step is to connect the cables to the motherboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables.
  • Page 45: I/O Ports

    Chapter 5: Advanced Motherboard Setup Figure 5-1. Front Control Panel Header Pins (JF1) Ground FP PWRLED 3.3 V HDD LED UID Switch NIC1 Activity LED 3.3V Stby 3.3V Stby NIC2 Activity LED OH/Fan Fail Blue LED Power Fail LED 3.3V Reset Reset Button Ground...
  • Page 46: Installing Memory

    UPER ERVER 5038D-i User's Manual Installing Memory Note: Check the Supermicro web site for recommended memory modules. CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Installing DIMMs 1. Insert the desired number of DIMMs into the memory slots in the following order: slot DIMMB2, DIMMA2, DIMMB1, DIMMA.
  • Page 47 Chapter 5: Advanced Motherboard Setup Towards the CPU Slot A1 Slot A2 (Blue Slot) Slot B1 Slot B2 (Blue Slot) Towards the edge of the motherboard Populating these DIMM modules with a pair of memory modules of the same type and same size will result in interleaved memory, which will improve memory performance.
  • Page 48 UPER ERVER 5038D-i User's Manual Possible System Memory Allocation & Availability Physical Memory Remaining (-Available) System Device Size (4 GB Total System Memory) Firmware Hub fl ash memory (System BIOS) 1 MB 3.99 Local APIC 4 KB 3.99 Area Reserved for the chipset 2 MB 3.99...
  • Page 49: Adding Pci Cards

    Chapter 5: Advanced Motherboard Setup Adding PCI Cards PCI Expansion Slots Three standard size PCI expansion (add-on) cards may be added to the system. When viewed from the chassis front, the card installs to the left rear of the system. PCI Card Installation Before installing a PCI add-on card, make sure it is supported by the card slot on the motherboard.
  • Page 50: Motherboard Details

    UPER ERVER 5038D-i User's Manual Motherboard Details Figure 5-4. SUPER X10SLL-F Layout USB6/7 COM1 COM2 USB4/5 LED1 BMC FW LAN1 LAN2 CTRL IPMI_LAN BIOS JPL2 JPL1 X10SLM-F/X10SLL(-F/SF/S) Rev. 1.02 IPMI Code BAR Code MAC Code T-SGPIO1 T-SGPIO2 I-SATA3 JSD1 I-SATA0...
  • Page 51 Chapter 5: Advanced Motherboard Setup Jumper Description Default C1/JI SMB to PCI Slots Off (Disabled) JPB1 BMC Enable Pins 1-2 (Enabled) JBR1 BIOS Recovery Pins 1-2 (Normal) JPG1 VGA Enable Pins 1-2 (Enabled) JPL1/JPL2 LAN1/LAN2 Enable Pins 1-2 (Enabled) JPME1 ME Recovery Pins 1-2 (Normal) JPME2...
  • Page 52: Connector Defi Nitions

    UPER ERVER 5038D-i User's Manual Connector Defi nitions ATX Power 24-pin Connector Pin Defi nitions (JPW1) Pin# Defi nition Pin # Defi nition Power Connectors +3.3V +3.3V The 24 - pin main power connector -12V +3.3V (JPW1) is used to provide power to the motherboard.
  • Page 53 Chapter 5: Advanced Motherboard Setup NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located LAN1/LAN2 LED Pin Defi nitions (JF1) on pins 11 and 12 of JF1, and the LED Pin# Defi nition connection for LAN Port 2 is on pins 9 9/11 3.3V Stby and 10.
  • Page 54 UPER ERVER 5038D-i User's Manual Power Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily Power Button Pin Defi nitions (JF1) contacting both pins will power on/off the Pin# Defi nition system. This button can also be confi g-...
  • Page 55 Chapter 5: Advanced Motherboard Setup Fan Headers Fan Header Pin Defi nitions The X10SLL-F has five fan headers Pin# Defi nition (Fan1 ~ Fan4 and FanA). These are 4-pin Ground (Black) fan headers and work with IPMI to moni- +12V (Red) tor and change fan speed as required Tachometer based on the system temperature.
  • Page 56 UPER ERVER 5038D-i User's Manual Trusted Platform Module Header Trusted Platform Module Header Pin Defi nitions This header is used to connect a Trusted Pin # Defi nition Pin # Defi nition Platform Module (TPM), available sepa- LCLK rately from a third-party vendor. A TPM is...
  • Page 57 Chapter 5: Advanced Motherboard Setup T-SGPIO 1/2 & 3-SGPIO 1/2 Headers Serial_Link-SGPIO Pin Defi nitions Two T-SGPIO (Serial-Link General Pur- Pin# Defi nition Defi nition pose Input/Output) headers are provided on the motherboard. These headers are Ground DATA Out used to communicate with the enclosure Load Ground management chip in the system.
  • Page 58: Jumper Settings

    UPER ERVER 5038D-i User's Manual Jumper Settings Explanation of Jumpers To modify the operation of the mother- board, jumpers can be used to choose Connector between optional settings. Jumpers cre- Pins ate shorts between two pins to change the function of the connector. Pin 1 is Jumper identifi...
  • Page 59 Chapter 5: Advanced Motherboard Setup PCI Slot SMB Enable PCI Slot SMB Enable/Disable Jumper Settings Use Jumpers JI C1/JI C2 to enable PCI-E Setting Defi nition SMB (System Management Bus) support Closed Enabled to improve system management for the Open (Default) Disabled PCI-E slots.
  • Page 60 UPER ERVER 5038D-i User's Manual Management Engine (ME) Recovery Use Jumper JPME1 to select ME Firmware Recovery mode, which will ME Recovery limit resource allocation for essential Jumper Settings system operation only in order to Jumper Setting Defi nition maintain normal power operation and...
  • Page 61: 5-10 Onboard Indicators

    Chapter 5: Advanced Motherboard Setup 5-10 Onboard Indicators LAN1/LAN2 LEDs The Ethernet ports (located beside the LAN LED VGA port) have two LEDs. On each Giga- Connection Speed Indication bit LAN port, one LED indicates activity LED State Defi nition when blinking while the other LED may be No connection or 10 Mb/s green, amber or off to indicate the speed...
  • Page 62: 5-11 Sata Drive Connections

    UPER ERVER 5038D-i User's Manual 5-11 SATA Drive Connections SATA Port Pin Defi nitions Pin # Defi nition SATA Ports Ground Two SATA 3.0 and four SATA 2.0 ports are included on the motherboard. See the table on the right for pin defi nitions for the Ground onboard SATA ports.
  • Page 63: 5-12 Installing Software

    Chapter 5: Advanced Motherboard Setup 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. After accessing the ftp site, go into the CDR_Images directory and locate the ISO fi...
  • Page 64 UPER ERVER 5038D-i User's Manual SuperDoctor® 5 The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface in Windows and Linux operating systems. The program moni- tors system health information such as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 65: 5-13 Onboard Battery

    Chapter 5: Advanced Motherboard Setup 5-13 Onboard Battery Please handle used batteries carefully. Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfi ll. Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly.
  • Page 66 UPER ERVER 5038D-i User's Manual Notes 5-28...
  • Page 67: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform simple maintenance on the SC731i-300B chassis. Following the component installation steps in the order given will eliminate most common problems. If some steps are unnecessary, skip ahead to the next step.
  • Page 68: Front Control Panel

    UPER ERVER 5038D-i User's Manual Front Control Panel The front control panel must be connected to the JF1 connector on the motherboard to provide you with system status and alarm indications. A ribbon cable has bundled these wires together to simplify this connection. Connect the cable from JF1 on the motherboard (making sure the red wire plugs into pin 1) to the appropriate comn- nector on the front control panel PCB (printed circuit board).
  • Page 69 Chapter 6: Advanced Chassis Setup Figure 6-2. Chassis Rear View Power Supply I/O Backplane (see Figure 5-2) PCI Expansion Slots...
  • Page 70: Front Bezel

    UPER ERVER 5038D-i User's Manual Front Bezel A bezel may be installed to cover the front of the chassis. Front Bezel Installation 1. Remove the dummy cover (A) on the peripheral drive bay. 2. Push the front bezel into place on the front of the chassis to complete the installation (see Figure 6-4).
  • Page 71: Removing The Chassis Cover

    Chapter 6: Advanced Chassis Setup Removing the Chassis Cover The left side cover of the chassis must be removed before replacing the system fan or installing and removing hard drives. Warning: Only qualifi ed service technicians should access the inside of the system. Except for short periods of time, do NOT operate the system without the cover in place.
  • Page 72: System Fans

    UPER ERVER 5038D-i User's Manual System Fans The SC731 includes a super quiet system fan that provides cooling for the chassis. No tools or screws are required to install the system fan. Fan Failure Under normal operation, the chassis fan and the power supply fan both run continu- ously.
  • Page 73: Drive Bay Installation

    Chapter 6: Advanced Chassis Setup Drive Bay Installation The SC731 chassis must be powered-down before hard drives can be removed from the hard drive carriers, which are not hot-swappable. SATA Drives The SATA drive IDs are preconfi gured as 0 through 3 in order from bottom to top. In order to access and install components in the chassis interior, it is necessary to rotate the hard drive cage.
  • Page 74 UPER ERVER 5038D-i User's Manual Release Tab (A) HDD Cage (B) Figure 6-6. Rotating the Hard Drive Cage Release Tabs Figure 6-7. Removing a Hard Drive Carrier from the Hard Drive Cage...
  • Page 75: Installing Drives In The Optional Drive Bays

    Chapter 6: Advanced Chassis Setup Installing Drives in the Optional Drive Bays The SC731 chassis has two empty drive bays that support optional devices such as a DVD-ROM. Installing an Optional Device 1. Power down the server and disconnect it from the power source. 2.
  • Page 76: Power Supply

    UPER ERVER 5038D-i User's Manual Power Supply The SC731 chassis includes a 300-watt power supply. The power supply has the ca- pability to automatically sense and operate with an input voltage of 100 or 240V AC. If it becomes necessary to replace the power supply, follow the instructions below.
  • Page 77: Chapter 7 Bios

    Chapter 7: BIOS Chapter 7 BIOS Introduction This chapter describes the AMI BIOS Setup Utility for the X10SLM-F/X10SLL-F/ X10SLL-SF/X10SLL-S . The ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens.
  • Page 78: How To Start The Setup Utility

    UPER ERVER 5038D-i User's Manual How to Start the Setup Utility Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility. From the main menu, you can access the other setup screens.
  • Page 79 Chapter 7: BIOS The following Main menu items will be displayed: System Time/System Date Use this option to change the system time and date. Highlight System Time or System Date using the arrow keys. Enter new values through the keyboard. Press the <Tab>...
  • Page 80: Advanced Setup Confi Gurations

    UPER ERVER 5038D-i User's Manual Advanced Setup Confi gurations Use the arrow keys to select Boot Setup and press <Enter> to access the submenu items: Warning: Take Caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency or an incorrect DRAM timing setting may cause system to become unstable.
  • Page 81 Chapter 7: BIOS Bootup Num-Lock This feature selects the Power-on state for the Numlock key. The options are Off and On. Wait For 'F1' If Error This feature forces the system to wait until the 'F1' key is pressed if an error oc- curs.
  • Page 82 UPER ERVER 5038D-i User's Manual  CPU Confi guration The following CPU information will be displayed: • Type of CPU • CPU Signature • Microcode Patch • Maximum CPU Speed • Minimum CPU Speed • CPU Speed • Processor Cores •...
  • Page 83 Chapter 7: BIOS Hyper-threading Select Enabled to support Intel Hyper-threading Technology to enhance CPU per- formance. The options are Enabled and Disabled. Active Processor Cores This feature determines how many CPU cores will be activated for each CPU. When all is selected, all cores in the CPU will be activated. (Please refer to Intel's web site for more information.) The options are All, 1, 2, and 3.
  • Page 84 UPER ERVER 5038D-i User's Manual CPU AES Select Enable to enable Intel CPU Advanced Encryption Standard (AES) Instruc- tions for CPU to enhance data integrity. The options are Enabled and Disabled. EIST EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically adjust processor voltage and core frequency in an effort to reduce power consump- tion and heat dissipation.
  • Page 85 Chapter 7: BIOS 1-Core Ratio Limit (Available when "Turbo Mode" is set to Enabled) This increases (multiplies) 1 clock speed in the CPU core in relation to the bus speed when one CPU core is active. Press "+" or "-" on your keyboard to change this value.
  • Page 86 UPER ERVER 5038D-i User's Manual CPU C3 Report (Available when "CPU C-States" is set to Enabled) Select Enabled to allow the BIOS to report the CPU C3 State (ACPI C2) to the operating system. During the CPU C3 State, the CPU clock generator is turned off.
  • Page 87 Chapter 7: BIOS LakeTiny Feature Select Enabled for LakeTing feature support. The options are Disabled and En- abled. ACPI T State Select Enabled for ACPI T state (processor throttling) feature support. The options are Disabled and Enabled. Chipset Confi guration WARNING: Setting the wrong values in the following sections may cause the system to malfunction.
  • Page 88 UPER ERVER 5038D-i User's Manual This item allows the generation confi guration of PEG0 on the PCI-E slot. The options are Auto, Gen1, Gen2 and Gen3. PEG1 - Gen X This item allows the generation confi guration of PEG1 on the PCI-E slot. The options are Auto, Gen1, Gen2 and Gen3.
  • Page 89 Chapter 7: BIOS • CAS Latency (tCL) • Minimum Delay Time • CAS to RAS (tRCDmin) • Row Precharge (tRPmin) • Active to Precharege (tRASmin) Memory Frequency Limiter This feature sets the limit of memory frequency for DIMM modules installed on the the motherboard.
  • Page 90 UPER ERVER 5038D-i User's Manual EHCI2 Select Enabled to enable EHCI (Enhanced Host Controller Interface) Controller 2 for USB 2.0 support. One EHCI controller must always be enabled. The settings are Enabled and Disabled.. Legacy USB Support This feature enables support for legacy USB devices. Select Auto to disable legacy support if USB devices are not present.
  • Page 91 Chapter 7: BIOS  SATA Confi guration of the SATA Devices and displays the following items: SATA Controllers This item Enables or Disables the built-in SATA controllers on the motherboard. The options are Enabled and Disabled. SATA Mode Selection This item selects the mode for the installed SATA drives. The options are IDE, AHCI and RAID.
  • Page 92 UPER ERVER 5038D-i User's Manual Serial ATA Port 0~ Port 5 This item displays the information detected on the installed SATA drives on the particular SATA port. • Model number of drive and capacity • Software Preserve Support If the item above - SATA Mode Select is set to RAID, the following items are...
  • Page 93 Chapter 7: BIOS VGA Palette Snoop Select Enabled to support VGA palette register snooping which will allow the PCI cards that do not contain their own VGA color palette to examine the video cards palette and mimic it for proper color display. The options are Disabled and Enabled.
  • Page 94: Acpi Settings

    UPER ERVER 5038D-i User's Manual ment) to boot the computer using a PXE device installed in a LAN port specifi ed. Select Disabled to prevent system boot using a device installed in a LAN port. The options are Disabled, PXE and iSCSI. The default setting for Onboard LAN1 Op- tion ROM is PXE.
  • Page 95 Chapter 7: BIOS • SPS Version • ME FW (Firmware) Status Value • ME FW State • ME FW Operation State • ME FW Error Code • ME NM FW Status Value • BIOS Booting Mode • Cores Disabled • ME FW SKU Information •...
  • Page 96: Console Redirection Settings

    UPER ERVER 5038D-i User's Manual SOL Change Settings This feature specifi es the base I/O port address and the Interrupt Request ad- dress of SOL Serial Port. Select Auto to let the BIOS automatically assign the base I/O and IRQ address. The options for Serial Port 2 are Auto, (IO=2F8h;...
  • Page 97 Chapter 7: BIOS Stop Bits A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2. Flow Control This feature allows the user to set the fl...
  • Page 98 UPER ERVER 5038D-i User's Manual Console Redirection (for EMS) Select Enabled to use a COM Port selected by the user for Console Redirection. The options are Enabled and Disabled.  Console Redirection Settings (for EMS) This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user.
  • Page 99: Event Logs

    Chapter 7: BIOS Event Logs  Change SMBIOS Event Log Settings Enabling/Disabling Options SMBIOS Event Log Change this item to enable or disable all features of the SMBIOS Event Logging during system boot. The options are Enabled and Disabled. Erasing Settings Erase Event Log If No is selected, data stored in the event log will not be erased.
  • Page 100: View Smbios Event Log

    UPER ERVER 5038D-i User's Manual SMBIOS Event Long Standard Settings Log System Boot Event This option toggles the System Boot Event logging to enabled or disabled. The options are Disabled and Enabled. MECI The Multiple Event Count Increment (MECI) counter counts the number of oc- curences a duplicate event must happen before the MECI counter is incremented.
  • Page 101 Chapter 7: BIOS  IPMI The following IPMI information will be displayed: • IPMI Firmware Revision • IPMI Status  System Event Log This feature is used to change the Sytem Event Log (SEL) confi guration. SEL Components - Change this item to enable or disable all features of System Event Logging.
  • Page 102 UPER ERVER 5038D-i User's Manual  BMC Network Confi guration LAN Channel 1: This feature allows the user to confi gure the settings for LAN1 Port. Update IPMI LAN Confi guration This feature allows the BIOS to implement any IP/MAC address changes at the next system boot.
  • Page 103: Boot Settings

    Chapter 7: BIOS Boot Settings Use this feature to confi gure Boot Settings: Set Boot Priority This option prioritizes the order of bootable devices that the system to boot from. Press [ENTER] on each entry from top to bottom to select devices. •...
  • Page 104 UPER ERVER 5038D-i User's Manual  Delete Boot Option This feature allows the user to delete a previously defi ned boot device from which the systems boots during startup. The settings are [any pre defi ned boot device]  Delete Driver Option This feature allows the user to delete a previously defi...
  • Page 105: Security Settings

    Chapter 7: BIOS Security Settings This menu allows the user to confi gure the following security settings for the system. • If the Administrator password is defi ned ONLY - this controls access to the BIOS setup ONLY. • If the User's password is defi ned ONLY - this password will need to be entered upon each system boot, and will also have Administrator rights in the setup.
  • Page 106: Save & Exit

    UPER ERVER 5038D-i User's Manual Save & Exit Select the Exit tab from the BIOS Setup Utility screen to enter the Exit BIOS Setup screen. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system confi...
  • Page 107 Chapter 7: BIOS Restore Optimized Defaults To set this feature, select Restore Defaults from the Exit menu and press <Enter>. These are factory settings designed for maximum system stability, but not for maximum performance. Save As User Defaults To set this feature, select Save as User Defaults from the Exit menu and press <En- ter>.
  • Page 108 UPER ERVER 5038D-i User's Manual Notes 7-32...
  • Page 109: Appendix A Bios Error Beep Codes

    Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue with bootup.
  • Page 110 UPER ERVER 5038D-i User's Manual Notes...
  • Page 111: Appendix B System Specifi Cations

    Appendix B: System Specifi cations Appendix B System Specifi cations Processors Single Intel® Xeon® E3-1200 v3 or 4th Gen Core™ i3 processor in an LGA1150 socket Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel C222 BIOS...
  • Page 112 UPER ERVER 5038D-i User's Manual Chassis SC731i-300B (Mini-tower) Dimensions: (WxHxD) 7.25 x 14.25 x 16.75 in. (184 x 362 x 425 mm) Weight Gross (Bare Bone): 23.5 lbs. (10.7 kg.) System Cooling One whisper-quiet 9-cm exhaust fan System Input Requirements...
  • Page 113 Appendix B: System Specifi cations Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000- 4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada), TUV Certifi...
  • Page 114 UPER ERVER 5038D-i User's Manual Notes...

Table of Contents