The Flue System; General; Suitable Flue Systems; Liner Installation - Osburn Matrix Inbuilt Installation And Operation Manual

Wood stove
Hide thumbs Also See for Matrix Inbuilt:
Table of Contents

Advertisement

  Osburn Matrix Inbuilt Installation and Operation Manual 
9 THE FLUE SYSTEM 
9.1 GENERAL  
The flue system, made up of the flue system and the flue between the wood inbuilt and the flue 
system, acts as the engine that drives your wood heating system. Even the best wood inbuilt will 
not function safely and efficiently as intended if it is not connected to a suitable flue system.  
The  heat  in  the  flue  gases  that  pass  from  the  wood  inbuilt  and  flue  into  the  flue  system  is  not 
waste heat. This heat is what the flue system uses to make the draft that draws in combustion air, 
keeps smoke inside the wood inbuilt and safely vents exhaust to outside. You can think of heat in 
the flue gas as the fuel the flue system uses to make draft. 
 
9.2 SUITABLE FLUE SYSTEMS 
Your wood inbuilt will provide optimum efficiency and performance when connected to a 150 mm 
diameter flue liner. The reduction of liner diameter to less than 150 mm should only be done if the 
total height of the masonry flue system is greater than 20 feet. 
 
9.3 LINER INSTALLATION 
For  appliances  discharging  combustion 
products  through  a  chimney,  the 
chimney 
shall 
be 
soundness  and  thoroughly  cleaned 
before  a  flue  pipe  is  installed.  The  air 
gap  between  the  flue  pipe  and  the 
chimney shall be open at the top of the 
chimney  to  the  extent  that  the  total 
opening  area  is  not  less  than  10  000 
2
mm
.    The  chimney  exit  shall  be  fitted 
with  means  to  prevent  significant 
ingress  of  water  and  debris,  and  such 
means shall be constructed and fitted to 
maintain  a  total  opening  area  at  the 
chimney  exit  of  not  less  than  10  000 
2
mm
.   
The  flue  pipe  to  inbuilt  used  in  the 
chimney shall comply with AS/NZS 2918. 
In  order  to  connect  the  wood  inbuilt  to 
the  flue  liner,  refer  to  Section  9.4  Flue 
liner installation.  
36  _ _____________________________________________________________________________   