Cabinet/Cutout
Dimensions
Cabinet tolerances +1/16"-0
(+1.6 mm, 0) unless otherwise noted.
10" (254 mm) to
combustible side
_- wall Min. both sides --_
_
1/2" (13 mm)
overhang,
both
sides
J
Cooktop platform
1" (25 mm) Min.
thickness
1 1/2" (38 mm)
typical
countertop
thickness
\
!
36" (914 mm)
typical
Cabinet/Countertop
Dimensions
- Front View
13" (330 mm)
max. 3
Hood
30" (762 mm)*
DRT304S
30" (762 mm)
36" (914 mm)**
36" (914mm)*
DRT366S
36" (914 mm)
42" (1067 mm)**
* Minimum ** Recommended
See note 2
18" (457 mm)"
Min.1, 3
30" (762 mm)
Min. 1
Top of
finished
counter
Cutout for
utility access
NOTE: Models DRT304S and DRT366S
are not approved for installation with a
raised vent.
Cabinet/Countertop
Dimensions
-
ISO View
1 Vertical to combustible
surface from cooktop grate level;
if installing an overhead vent hood, also check the hood
specifications
for minimum required clearances.
2 See Cabinet/Countertop
Dimensions
- Top View
3 Not applicable for cabinets more than a horizontal
distance of 10" (254mm) from the edge of the cooktop.