WATER SUPPLY
A WARNING:
Plumbing connections must comply with applicable sanitary, safety and plumbing codes in your area.
The machine can be connected to either a hot or cold water supply. If a cold water supply is used, the washing times will be
longer but the performance will not be affected.
The dishwasher comes with a 6-foot PEXwater supply line that has a 3/8" NPTfemale connection.
After determining where the water supply line will enter under the sink, drill a 1-1/2" access hole and run the line to the approxi-
mate inlet valve location shown in the fgure below. The water line inlet valve is on the right rear of the machine.
For service convenience, a shut-off valve (not supplied) should be installed in the supply line in an easily accessible location, such
as, beneath the sink.
It is important that the water supply line and the shut-off valve have a sumcient flow volume. At last 3 gallons (12 liters) per
minute must be able to pass through the line. The water pressure should be 4.2-140 psi.
ADVERTENCIA:
Las conexiones de plomer[a deben cumplir con los cbdigos sanitarios, de seguridad y de plomer[a vigentes en su _rea.
La m_quina puede conectarse al suministro de agua caliente o de agua frfa. Si se utiliza el suministro de agua if[a, los tlempos
de lavado ser_n m_s prolongados pero el desempe_o no se ver_ afectado.
El lavavajillas viene con una I[nea de suministro de agua de polietileno reticulado de 6 pies que cuenta con una conexibn hem-
bra NPT de 3/8".
Despu_s de establecer el lugar en donde se colocar_ la I[nea de suministro de agua debajo del fregadero, perfore un orificio de
acceso de !-!/2" y distribuya la I[nea hasta la ubicacibn aproximada de la v_lvula de ingreso indicada en la imagen de abajo. La
vdlvula de ingreso de la I[nea de agua se encuentra en la parte trasera derecha de la m_quina.
Para mayor comodidad cuando se realiza una reparacibn, debe instalarse una v_lvula de cierre (no provista) en la I[nea de sum-
inistro en una ubicacibn f_cilmente accesible, coma par ejemplo, debajo del fregadero.
Resulta importante que la I[nea de suministro de agua y la v_lvula de cierre tengan un volumen de flujo suficiente. Par Io menos
3 galones (12 litros) par minuto deben poder pasar a travbs de la I[nea. La presibn del agua debe set de 4.2-!40 psi.
EASYINSTALL
CONNECTIONS
PEXtubing with 3/8" compression fitting
PEXtubing has u 95-year spec life. Fits Ameri-
can dishwasher water supply valves. Be sure to
install the O-Ring which is attached to the PE×
tubing in a plastic bag.
Drain hose boot
Ready to be cut to desired drain
connection. Only one clamp
required.
Electrical cord
!20 volts, !5 amp cord is supplied with the
dishwasher.
A WARNING:
Do not use an extension
cord for this appliance.
ADVERTENCIA:
No utilice
un cable de extensi6n
con este
aparato.
WARNING:
In order to prevent heat damage to the inlet valve,
all solder connections
must be m(]de before the
water line is connected to the dishwasher.
D VERTEN CIA:
A fin de evitGr dGSos provocGdos par el cGIor e la
vblvulo de entradG, deben reGlizGrse todGs las con-
exiones mediGnte soldGdurG antes de conectGr IG
Ifnee de aguG al IGvavajillGs.
#r
-1_
_-=_---='-==,_l
_:'=====-=
t_
E_
(1)',:
Eg
Ig I
(2) ,,
_
J
IF
h
1. Water supply
2. Water supply valve to dishwasher
(not supplied)
NOTE:
Be sure to run the PEX tubing through the hole to sink
compartment
before moving the dishwasher
into position.