ELECTRICAL CONNECTIONS (CANT)
Grounding
Instructions-Power
Cord Models
This appliance must be grounded. In the event of a
malfunction
or breakdown, grounding
will reduce
the risk of electric shock by providing a path of
least resistance for electric current. This appliance
is equipped with a cord having an equipment-
grounding
conductor
and a grounding
plug. The
plug must be plugged into an appropriate
outlet
that is installed and grounded in accordance
with all
local codes and ordinances.
,& WARNING:
Make sure the water supply line, drain line and
branch circuit wiring do not touch any exposed ter-
minals of dishwasher wiring.
AADVERTENCIA:
Verifique que la linea de suministro de agua, linea
de drenuje y cableudo del circuito derivudo no
toquen ningunu terminal expuestu del cubleudo del
luvuvujillus.
The improper
connection
of the equipment
grounding
conductor
can result in a risk
of electric shock. Check with a qualified
electrician
or service representative
if you
are in doubt that the appliance
is properly
grounded.
La conexi6n incorrecta
del conductor de
conexi6n a tierra del equipo puede resultar
en choque ei_ctrico.
Consulte con un
electricista
calificado
o representante
de servicio si tiene dudas de la conexi6n
a tierra del aparato.
The power-supply
receptacle for the dishwasher is
to be installed in a cabinet or on a wall adjacent to
the undercounter
space in which the dishwasher is
to be install.
,& WARNING:
Do not use an extension cord for this appliance.
ADVERTENCIA:
No utilice un cable de extensi6n
con este aparato.
a_
/I..
- i
NOTE:
Access holes should be !-!/2"
max (38.! mm max) in diameter
wlfl_ no sT_arpe_Iges.
If the cord is not long enough, or if a hard-wire installation
is needed, follow the steps below to complete the electrical
connection.
WARNING:
Before starting this procedure, be sure the power is
turned off at the breaker/fuse
box.
1. Connect supply cable with a UL-listed strain relief bushing (if
nonmetallic cable is to be used).
2. Connect branch circuit white
lead to N lead on filter.
3. Connect branch circuit
black
lead to L lead on filter.
/4.Connect ground wire
to ground connection
screw on the bottom.
If the edges of the opening is wood it must be
smooth and rounded.
If the edges of the opening
is metal it must be covered by an edge protector
provided for this purpose by the manufacturer.
Be
careful when installing or removing the dishwasher,
to reduce the likelihood of damage to the power-
supply cord.
10
AADVERTENCIA:
Antes de comenzar este procedimiento, aseg0rese de haber
apagado la energ[a el6ctrica desde el interruptor/caja de
fusibles.
1. Conecte el cable de suministro con un casquillo de alivio de
tensi6n aprobado par UL (si no se va a utilizar un cable no
met61ico).
2. Conecte el cable blanco de circuito derivado al cable N del
filtro.
3. Conecte el cable negro de circuito derivado al cable L del
filtro.
/4.Conecte el cable a tierra al tornillo de conexi6n a tierra en la
parte inferior.
NOTE:
When doing a hard-wire installation, you must remove the
supplied power cord.